ADC KENTROX =========== DATASMART T3/E3 SMDSU MODEL 1596X (AC POWER) Card Type T3/E3 CSU/DSU Chipset Unidentified T3/E3 Transfer Rate 34.368Mbps (E3) T3/E3 Protocol M13, C-Bit, G.751, B8ZS Frame Type Unidentified Data Bus Serial +------------------------------------------------------------+ | CONNECTIONS | |------------------------------------------------------------| | Function | Label | Function | Label | |----------------------+-------+---------------------+-------| | Monitor jack | CN1 | T3/E3 line in/out | CN8 | |----------------------+-------+---------------------+-------| | Monitor jack | CN2 | T3/E3 line in/out | CN9 | |----------------------+-------+---------------------+-------| | DCE serial control | CN3 | RS-422 auxiliary | CN10 | | port | | clock port | | |----------------------+-------+---------------------+-------| | DTE serial control | CN4 | AC power in | CN11 | | port | | | | |----------------------+-------+---------------------+-------| | V.35 serial data | CN5 | Alarm relay (see | SC1 | | port via DB-25 | | pinout below) | | | connector | | | | |----------------------+-------+---------------------+-------| | HSSI serial data | CN6 | Alarm cutoff switch | S5 | | port | | | | |----------------------+-------+---------------------+-------| | HSSI serial data | CN7 | | | | port | | | | |------------------------------------------------------------| | Note:Standard V.35 serial port is provided on an | | included adapter cable. | +------------------------------------------------------------+ +------------------------------------------------------------+ | SC1 PINOUT | |------------------------------------------------------------| | Function | Screw | Function | Screw | |----------------------+-------+---------------------+-------| | Normally closed | 1 | Normally open | 3 | | contact | | contact | | |----------------------+-------+---------------------+-------| | Signal common | 2 | | | +------------------------------------------------------------+ +------------------------------------------------------------+ | USER CONFIGURABLE SETTINGS | |------------------------------------------------------------| | Setting | Label | Position | |-----------------------------------------+-------+----------| |>> | Control port parity disabled | S1/3 | On | |---+-------------------------------------+-------+----------| | | Control port parity enabled | S1/3 | Off | |---+-------------------------------------+-------+----------| |>> | Control port parity set to odd | S1/4 | On | |---+-------------------------------------+-------+----------| | | Control port parity set to even | S1/4 | Off | |---+-------------------------------------+-------+----------| |>> | Control port uses 8 data bits | S1/5 | On | |---+-------------------------------------+-------+----------| | | Control port uses 7 data bits | S1/5 | Off | |---+-------------------------------------+-------+----------| |>> | Control port uses 1 stop bit | S1/6 | On | |---+-------------------------------------+-------+----------| | | Control port uses 2 stop bits | S1/6 | Off | |---+-------------------------------------+-------+----------| |>> | Alarm reporting disabled | S1/7 | On | |---+-------------------------------------+-------+----------| | | Alarm reporting enabled | S1/7 | Off | |---+-------------------------------------+-------+----------| |>> | Alarm reporting output to DCE | S1/8 | On | | | control port | | | |---+-------------------------------------+-------+----------| | | Alarm reporting output to DTE | S1/8 | Off | | | control port | | | |---+-------------------------------------+-------+----------| |>> | Adapter in SMDS mode | S2/3 | On | |---+-------------------------------------+-------+----------| | | Adapter in DSU mode | S2/3 | Off | |---+-------------------------------------+-------+----------| |>> | T3/E3 receive equalization enabled | S2/4 | On | |---+-------------------------------------+-------+----------| | | T3/E3 receive equalization disabled | S2/4 | Off | |---+-------------------------------------+-------+----------| |>> | T3/E3 transmit Line Build Out out | S2/5 | On | |---+-------------------------------------+-------+----------| | | T3/E3 transmit Line Build Out in | S2/5 | Off | |---+-------------------------------------+-------+----------| |>> | Factory configured - do not alter | S2/6 | On | |---+-------------------------------------+-------+----------| |>> | Factory configured - do not alter | S2/7 | On | |---+-------------------------------------+-------+----------| |>> | Factory configured - do not alter | S2/8 | On | +------------------------------------------------------------+ +------------------------------------------------------------+ | CONTROL PORT SPEED SELECTION | |------------------------------------------------------------| | Setting | S1/1 | S1/2 | |-------------------------+-----------------+----------------| |>> | 9600bps | On | On | |----+--------------------+-----------------+----------------| | | 4800bps | On | Off | |----+--------------------+-----------------+----------------| | | 2400bps | Off | On | |----+--------------------+-----------------+----------------| | | 1200bps | Off | Off | +------------------------------------------------------------+ +------------------------------------------------------------+ | PROTOCOL SELECTION | |------------------------------------------------------------| | Setting | S2/1 | S2/2 | |------------------------+-----------------+-----------------| |>> | T3 MI3 | On | On | |---+--------------------+-----------------+-----------------| | | T3 C-Bit | On | Off | |---+--------------------+-----------------+-----------------| | | E3 G.751 | Off | On | |---+--------------------+-----------------+-----------------| | | E3 G.751 | Off | Off | +------------------------------------------------------------+ +------------------------------------------------------------+ | THUMBWEEL FUNCTION SELECTION | |------------------------------------------------------------| | Function | S3 | S4 | S5 | |-------------------------------+--------+----------+--------| | Reset loopback tests | Pushed | Position | Not | | | | 0 | pushed | |-------------------------------+--------+----------+--------| | Begin remote line loopback | Pushed | Position | Not | | test | | 1 | pushed | |-------------------------------+--------+----------+--------| | Begin remote payload loopback | Pushed | Position | Not | | test | | 2 | pushed | |-------------------------------+--------+----------+--------| | Reset to factory defaults and | Pushed | Position | Pushed | | switch settings | for 2 | 3 | for 2 | | | sec. | | sec. | |-------------------------------+--------+----------+--------| | Begin near-end line loopback | Pushed | Position | Not | | test | | 4 | pushed | |-------------------------------+--------+----------+--------| | Begin near-end payload | Pushed | Position | Not | | loopback test | | 5 | pushed | |-------------------------------+--------+----------+--------| | Begin near-end local loopback | Pushed | Position | Not | | test | | 6 | pushed | |-------------------------------+--------+----------+--------| | Begin data near-end terminal | Pushed | Position | Not | | loopback test | | 7 | pushed | |-------------------------------+--------+----------+--------| | Reset SMDSU address to | Pushed | Position | Pushed | | 00:00:000 | for 2 | 7 | for 2 | | | sec. | | sec. | |------------------------------------------------------------| | Note:S3 and S5 must always be held for at least | | one-half of one second for the above functions to | | take effect. | +------------------------------------------------------------+ +------------------------------------------------------------+ | DIAGNOSTIC LED(S) | |------------------------------------------------------------| | LED | Color | Status | Condition | |------+--------+----------+---------------------------------| | PWR | Green | On | Power is on | |------+--------+----------+---------------------------------| | PWR | Red | On | Self-test failed | |------+--------+----------+---------------------------------| | PWR | N/A | Off | Power is off | |------+--------+----------+---------------------------------| | LOOP | Yellow | On | Local loopback test in progress | |------+--------+----------+---------------------------------| | LOOP | Yellow | Blinking | Remote loopback test in | | | | | progress | |------+--------+----------+---------------------------------| | LOOP | Yellow | Off | Loopback test not in progress | |------+--------+----------+---------------------------------| | SEND | Yellow | On | Test code being sent | |------+--------+----------+---------------------------------| | SEND | Yellow | Blinking | Remote loopback test may be in | | | | | progress but cannot be verified | |------+--------+----------+---------------------------------| | SEND | Yellow | Off | Test code not being sent | |------+--------+----------+---------------------------------| | ALM | Red | On | Alarm condition detected and | | | | | awaiting user intervention | |------+--------+----------+---------------------------------| | ALM | Green | On | Alarm condition detected; user | | | | | intervention in progress | |------+--------+----------+---------------------------------| | ALM | N/A | Off | Alarm condition not detected | |------+--------+----------+---------------------------------| | RCV | Green | On | DSU is receiving data from | | | | | network | |------+--------+----------+---------------------------------| | RCV | Green | Off | DSU is not receiving data from | | | | | network | |------+--------+----------+---------------------------------| | XMT | Green | On | DSU is transmitting data to | | | | | network | |------+--------+----------+---------------------------------| | XMT | Green | Off | DSU is not transmitting data to | | | | | network | |------+--------+----------+---------------------------------| | FEI | Red | On | Remote is out of PLCP lock | |------+--------+----------+---------------------------------| | FEI | Red | Blinking | Remote PLCP Code Violation | | | | | detected | |------+--------+----------+---------------------------------| | FEI | Red | Off | Remote PLCP normal | |------+--------+----------+---------------------------------| | NEI | Red | On | Local DSU is out of PLCP lock | |------+--------+----------+---------------------------------| | NEI | Red | Blinking | Local DSU PLCP Code Violation | | | | | detected | |------+--------+----------+---------------------------------| | NEI | Red | Off | Local DSU PLCP normal | |------+--------+----------+---------------------------------| | TXD | Yellow | On | Control port is transmitting | | | | | data | |------+--------+----------+---------------------------------| | TXD | Yellow | Off | Control port is not | | | | | transmitting data | +------------------------------------------------------------+ +------------------------------------------------------------+ | DIAGNOSTIC LED(S) (CON'T) | |------------------------------------------------------------| | LED | Color | Status | Condition | |------+--------+----------+---------------------------------| | RXD | Yellow | On | Control port is receiving data | |------+--------+----------+---------------------------------| | RXD | Yellow | Off | Control port is not receiving | | | | | data | |------+--------+----------+---------------------------------| | TA | Yellow | On | V.24 DTR or V.35 TA signal is | | | | | high | |------+--------+----------+---------------------------------| | TA | Yellow | Off | V.24 DTR or V.35 TA signal is | | | | | low | |------+--------+----------+---------------------------------| | CA | Yellow | On | V.24 DCD or V.35 CA signal is | | | | | high | |------+--------+----------+---------------------------------| | CA | Yellow | Off | V.24 DCD or V.35 CA signal is | | | | | low | |------+--------+----------+---------------------------------| | DATA | Green | On | Valid data signal detected | |------+--------+----------+---------------------------------| | DATA | Green | Off | No valid signal detected | |------+--------+----------+---------------------------------| | CV | Red | On | Code Violation error detected | |------+--------+----------+---------------------------------| | CV | Red | Off | Code Violation error not | | | | | detected | |------+--------+----------+---------------------------------| | LOS | Red | On | Loss Of Signal condition | | | | | detected | |------+--------+----------+---------------------------------| | LOS | Red | Off | Loss Of Signal condition not | | | | | detected | |------+--------+----------+---------------------------------| | OOF | Red | On | Signal is out of frame | | | | | synchronization | |------+--------+----------+---------------------------------| | OOF | Red | Off | Signal is not out of frame | | | | | synchronization | |------+--------+----------+---------------------------------| | AIS | Red | On | Alarm Indication Signal | | | | | condition detected | |------+--------+----------+---------------------------------| | AIS | Red | Off | Alarm Indication Signal | | | | | condition not detected | |------+--------+----------+---------------------------------| | YEL | Yellow | On | Remote Yellow Alarm condition | | | | | detected | |------+--------+----------+---------------------------------| | YEL | Yellow | Blinking | Local Yellow Alarm condition | | | | | detected | |------+--------+----------+---------------------------------| | YEL | Yellow | Off | Yellow Alarm condition not | | | | | detected | +------------------------------------------------------------+