ADC KENTROX =========== CROSSPATH MINI-DCS MODEL 77710 Card Type T1 CSU/DSU Chipset Unidentified T1 Transfer Rate 1.544Mbps T1 Protocol AMI, B8ZS Frame Type Unidentified Data Bus Serial +------------------------------------------------------------+ | CONNECTIONS | |------------------------------------------------------------| | Function | Label | Function | Label | |-------------------------+-------+------------------+-------| | T1 line out 4 (network | CN1 | Serial control | CN5 | | interface) | | port | | |-------------------------+-------+------------------+-------| | T1 line out 3 (network | CN2 | V.35 serial data | CN6 | | interface) | | port 2 | | |-------------------------+-------+------------------+-------| | T1 line out 2 (network | CN3 | V.35 serial data | CN7 | | interface) | | port 1 | | |-------------------------+-------+------------------+-------| | T1 line out 1 (network | CN4 | AC power in | CN8 | | interface) | | | | |------------------------------------------------------------| | Note:Standard V.35 serial ports are provided on | | included adapter cables. | +------------------------------------------------------------+ +------------------------------------------------------------+ | DIAGNOSTIC LED(S) | |------------------------------------------------------------| | LED | Color | Status | Condition | |-------+--------+--------+----------------------------------| | POWER | Green | On | Power is on | |-------+--------+--------+----------------------------------| | POWER | Red | On | Self-test failed | |-------+--------+--------+----------------------------------| | POWER | N/A | Off | Power is off | |-------+--------+--------+----------------------------------| | TXD1 | Yellow | On | Data port 1 is transmitting data | | | | | to network | |-------+--------+--------+----------------------------------| | TXD1 | Yellow | Off | Data port 1 is not transmitting | | | | | data to network | |-------+--------+--------+----------------------------------| | RXD1 | Yellow | On | Data port 1 is receiving data | | | | | from network | |-------+--------+--------+----------------------------------| | RXD1 | Yellow | Off | Data port 1 is not receiving | | | | | data from network | |-------+--------+--------+----------------------------------| | CTS1 | Yellow | On | Data port 1 CTS is high | |-------+--------+--------+----------------------------------| | CTS1 | Yellow | Off | Data port 1 CTS is low | |-------+--------+--------+----------------------------------| | RTS1 | Yellow | On | Data port 1 RTS is high | |-------+--------+--------+----------------------------------| | RTS1 | Yellow | Off | Data port 1 RTS is low | |-------+--------+--------+----------------------------------| | TXD2 | Yellow | On | Data port 2 is transmitting data | | | | | to network | |-------+--------+--------+----------------------------------| | TXD2 | Yellow | Off | Data port 2 is not transmitting | | | | | data to network | |-------+--------+--------+----------------------------------| | RXD2 | Yellow | On | Data port 2 is receiving data | | | | | from network | |-------+--------+--------+----------------------------------| | RXD2 | Yellow | Off | Data port 2 is not receiving | | | | | data from network | |-------+--------+--------+----------------------------------| | CTS2 | Yellow | On | Data port 2 CTS is high | |-------+--------+--------+----------------------------------| | CTS2 | Yellow | Off | Data port 2 CTS is low | |-------+--------+--------+----------------------------------| | RTS2 | Yellow | On | Data port 2 RTS is high | |-------+--------+--------+----------------------------------| | RTS2 | Yellow | Off | Data port 2 RTS is low | +------------------------------------------------------------+ +------------------------------------------------------------+ | DIAGNOSTIC LED(S) (CON'T) | |------------------------------------------------------------| | LED | Color | Status | Condition | |------+--------+----------+---------------------------------| | OOF1 | Green | On | T1 line 1 link is synchronized | |------+--------+----------+---------------------------------| | OOF1 | Red | On | T1 line 1 signal is out of | | | | | frame synchronization | |------+--------+----------+---------------------------------| | OOF1 | N/A | Off | T1 line 1 signal is not out of | | | | | frame synchronization | |------+--------+----------+---------------------------------| | AIS1 | Red | On | Loss of Signal condition | | | | | detected on T1 line 1 | |------+--------+----------+---------------------------------| | AIS1 | Red | Blinking | Alarm Indication Signal | | | | | condition detected on T1 line 1 | |------+--------+----------+---------------------------------| | AIS1 | Red | Off | Valid signal detected on T1 | | | | | line 1 | |------+--------+----------+---------------------------------| | CV1 | Red | Blinking | CRC error detected on T1 line 1 | |------+--------+----------+---------------------------------| | CV1 | Red | Off | CRC error not detected on T1 | | | | | line 1 | |------+--------+----------+---------------------------------| | TST1 | Yellow | On | Yellow alarm condition detected | | | | | on T1 line 1 | |------+--------+----------+---------------------------------| | TST1 | Yellow | Blinking | Loopback test in progress on T1 | | | | | line 1 | |------+--------+----------+---------------------------------| | TST1 | Yellow | Off | Yellow alarm condition not | | | | | detected and no loopback test | | | | | in progress on T1 line 1 | |------+--------+----------+---------------------------------| | OOF2 | Green | On | T1 line 2 link is synchronized | |------+--------+----------+---------------------------------| | OOF2 | Red | On | T1 line 2 signal is out of | | | | | frame synchronization | |------+--------+----------+---------------------------------| | OOF2 | N/A | Off | T1 line 2 signal is not out of | | | | | frame synchronization | |------+--------+----------+---------------------------------| | AIS2 | Red | On | Loss of Signal condition | | | | | detected on T1 line 2 | |------+--------+----------+---------------------------------| | AIS2 | Red | Blinking | Alarm Indication Signal | | | | | condition detected on T1 line 2 | |------+--------+----------+---------------------------------| | AIS2 | Red | Off | Valid signal detected on T1 | | | | | line 2 | |------+--------+----------+---------------------------------| | CV2 | Red | Blinking | CRC error detected on T1 line 2 | |------+--------+----------+---------------------------------| | CV2 | Red | Off | CRC error not detected on T1 | | | | | line 2 | |------+--------+----------+---------------------------------| | TST2 | Yellow | On | Yellow alarm condition detected | | | | | on T1 line 2 | |------+--------+----------+---------------------------------| | TST2 | Yellow | Blinking | Loopback test in progress on T1 | | | | | line 2 | |------+--------+----------+---------------------------------| | TST2 | Yellow | Off | Yellow alarm condition not | | | | | detected and no loopback test | | | | | in progress on T1 line 2 | |------+--------+----------+---------------------------------| | OOF3 | Green | On | T1 line 3 link is synchronized | |------+--------+----------+---------------------------------| | OOF3 | Red | On | T1 line 3 signal is out of | | | | | frame synchronization | |------+--------+----------+---------------------------------| | OOF3 | N/A | Off | T1 line 3 signal is not out of | | | | | frame synchronization | |------+--------+----------+---------------------------------| | AIS3 | Red | On | Loss of Signal condition | | | | | detected on T1 line 3 | |------+--------+----------+---------------------------------| | AIS3 | Red | Blinking | Alarm Indication Signal | | | | | condition detected on T1 line 3 | |------+--------+----------+---------------------------------| | AIS3 | Red | Off | Valid signal detected on T1 | | | | | line 3 | |------+--------+----------+---------------------------------| | CV3 | Red | Blinking | CRC error detected on T1 line 3 | |------+--------+----------+---------------------------------| | CV3 | Red | Off | CRC error not detected on T1 | | | | | line 3 | |------+--------+----------+---------------------------------| | TST3 | Yellow | On | Yellow alarm condition detected | | | | | on T1 line 3 | |------+--------+----------+---------------------------------| | TST3 | Yellow | Blinking | Loopback test in progress on T1 | | | | | line 3 | |------+--------+----------+---------------------------------| | TST3 | Yellow | Off | Yellow alarm condition not | | | | | detected and no loopback test | | | | | in progress on T1 line 3 | |------+--------+----------+---------------------------------| | OOF4 | Green | On | T1 line 4 link is synchronized | |------+--------+----------+---------------------------------| | OOF4 | Red | On | T1 line 4 signal is out of | | | | | frame synchronization | |------+--------+----------+---------------------------------| | OOF4 | N/A | Off | T1 line 4 signal is not out of | | | | | frame synchronization | +------------------------------------------------------------+ +------------------------------------------------------------+ | DIAGNOSTIC LED(S) (CON'T) | |------------------------------------------------------------| | LED | Color | Status | Condition | |------+--------+----------+---------------------------------| | AIS4 | Red | On | Loss of Signal condition | | | | | detected on T1 line 4 | |------+--------+----------+---------------------------------| | AIS4 | Red | Blinking | Alarm Indication Signal | | | | | condition detected on T1 line 4 | |------+--------+----------+---------------------------------| | AIS4 | Red | Off | Valid signal detected on T1 | | | | | line 4 | |------+--------+----------+---------------------------------| | CV4 | Red | Blinking | CRC error detected on T1 line 4 | |------+--------+----------+---------------------------------| | CV4 | Red | Off | CRC error not detected on T1 | | | | | line 4 | |------+--------+----------+---------------------------------| | TST4 | Yellow | On | Yellow alarm condition detected | | | | | on T1 line 4 | |------+--------+----------+---------------------------------| | TST4 | Yellow | Blinking | Loopback test in progress on T1 | | | | | line 4 | |------+--------+----------+---------------------------------| | TST4 | Yellow | Off | Yellow alarm condition not | | | | | detected and no loopback test | | | | | in progress on T1 line 4 | +------------------------------------------------------------+