BOCA RESEARCH, INC. =================== BOCA 112K DYNAMICDUO Card Type Modem, Fax Chip Set Unidentified Maximum Modem Rate 56Kbps Maximum Fax Rate 14.4Kbps Data Modulation Bell 103A/212A Protocol ITU-T V.21, V.22, V.22bis, V.22A/B, V.23, V.32, V.32bis, V.34 Fax Modulation ITU-T V.17, V.21CH2, V.27ter, V.29, Protocol V.33 Error MNP10-EC, MNP5, V.42, V.42bis Correction/Compression Fax Class Class I Data Bus 32-bit PCI Card Size Three-quarter length, full-height card +------------------------------------------------------------+ | CONNECTIONS | |------------------------------------------------------------| | Function | Label | Function | Label | |------------------------------------------------------------| | Line in | CN1 | Line out | CN2 | +------------------------------------------------------------+ +------------------------------------------------------------+ | SUPPORTED COMMAND SET | |------------------------------------------------------------| | Basic AT Commands | |------------------------------------------------------------| | AT, '+++', A/ | |------------------------------------------------------------| | A, E, H, M, O, Q, V, W, X, Y, Z | |------------------------------------------------------------| | &C, &P, &T, &V, &W, &Y | |------------------------------------------------------------| | Extended AT Commands | |------------------------------------------------------------| | \K, \N | |------------------------------------------------------------| | %C, %E, %L, %Q | |------------------------------------------------------------| | S Registers | |------------------------------------------------------------| | S0, S1, S2, S3, S4, S5, S6, S7, S8, S9, S10, S11, S12, | | S14, S16, S18, S21, S22, S23, S24, S25, | |------------------------------------------------------------| | S26, S27, S28, S29, S30, S31, S32, S33, S36, S37, S38, | | S39, S40, S41, S82, S91, S92, S95 | |------------------------------------------------------------| | Special Commands | |------------------------------------------------------------| | +MS | |------------------------------------------------------------| | Note: See MHI Help File for full command documentation. | +------------------------------------------------------------+ Proprietary AT Command Set +------------------------------------------------------------+ | AUTO-MODE DETECTION | |------------------------------------------------------------| | Type: | Configuration | |--------------+---------------------------------------------| | Format: | AT [cmds] Nn [cmds] | |--------------+---------------------------------------------| | Description: | Selects various options for the automatic | | | detection and negotiation of protocols | | | during the handshake process if the modem | | | is communicating with a remote modem of | | | dissimilar speed. | |--------------+---------------------------------------------| | Command | Function | |--------------+---------------------------------------------| | N0 | Auto-mode detection disabled | |--------------+---------------------------------------------| | i N1 | Auto-mode detection enabled | +------------------------------------------------------------+ +------------------------------------------------------------+ | COMMUNICATIONS MODE | |------------------------------------------------------------| | Type: | Configuration | |--------------+---------------------------------------------| | Format: | AT [cmds] &Qn [cmds] | |--------------+---------------------------------------------| | Description: | Selects communications mode options | |--------------+---------------------------------------------| | Command | Mode | |--------------+---------------------------------------------| | i &Q0 | Asynchronous mode, serial port speed | | | follows connect speed. | |--------------+---------------------------------------------| | &Q5 | Error correction mode | |--------------+---------------------------------------------| | &Q6 | Buffered asynchronous mode | +------------------------------------------------------------+ +------------------------------------------------------------+ | DATA SET READY (DSR) | |------------------------------------------------------------| | Type: | Configuration | |--------------+---------------------------------------------| | Format: | AT [cmds] &Sn [cmds] | |--------------+---------------------------------------------| | Description: | Selects DSR options | |--------------+---------------------------------------------| | Command | Function | |--------------+---------------------------------------------| | &S0 | DSR forced high | |--------------+---------------------------------------------| | i &S1 | DSR high only while modem is handshaking or | | | connected | +------------------------------------------------------------+ +------------------------------------------------------------+ | DATA TERMINAL READY (DTR) | |------------------------------------------------------------| | Type: | Configuration | |---------------+--------------------------------------------| | Format: | AT [cmds] &Dn [cmds] | |---------------+--------------------------------------------| | Description: | Selects modem response to DTR | |------------------------------------------------------------| | Note: The action each variant of &D causes depends on | | the setting of &Q | |------------------------------------------------------------| | &Q Setting | &D0 | &D1 | &D2 | &D3 | |------------------+----------+----------+---------+---------| | i &Q0, &Q5, &Q6 | NONE | Command | Command | Command | | | | 2 | 3 | 4 | |------------------+----------+----------+---------+---------| | &Q1, &Q4 | Command | Command | Command | Command | | | 1 | 2 | 3 | 4 | |------------------+----------+----------+---------+---------| | &Q2, &Q4 | Command | Command | Command | Command | | | 3 | 3 | 3 | 3 | |------------------------------------------------------------| | Command | Function | |---------------+--------------------------------------------| | i Command 0 | Modem does not respond to DTR | |---------------+--------------------------------------------| | Command 1 | Modem goes to command mode after DTR goes | | | is off | |---------------+--------------------------------------------| | Command 2 | Modem goes to command mode and disconnects | | | (hangs up) after DTR goes off; Auto-Answer | | | is disabled. | |---------------+--------------------------------------------| | Command 3 | Modem is initialized after DTR goes off | +------------------------------------------------------------+ +------------------------------------------------------------+ | DIAL | |------------------------------------------------------------| | Type: | Immediate | |--------------+---------------------------------------------| | Format: | AT [cmds] D<#> [cmds] | |--------------+---------------------------------------------| | Description: | Dials telephone number according to any | | | modifiers included in the string | |--------------+---------------------------------------------| | Note: | Any combination of modifiers can be used to | | | produce the desired dial functions in | | | sequence. | |--------------+---------------------------------------------| | Command | Function | |--------------+---------------------------------------------| | DL | Re-dial last number | |--------------+---------------------------------------------| | DP | Pulse dialing enabled | |--------------+---------------------------------------------| | DS=n | Dial stored telephone number n | |--------------+---------------------------------------------| | DT | Tone dialing enabled/Pulse dialing disabled | |--------------+---------------------------------------------| | DW | Dialing resumed following dial tone | | | detection | |--------------+---------------------------------------------| | D, | Dialing paused for amount of time specified | | | in S8 register | |--------------+---------------------------------------------| | D! | Flash function initiated. Modem commanded | | | to go off-hook for specified time before | | | returning on-hook. | |--------------+---------------------------------------------| | D@ | Wait for Quite Answer function enabled. | | | Modem waits until a "quiet answer," a | | | ring-back signal followed by silence up to | | | the time specified in S7, is received prior | | | to executing the rest of the dial string. | |--------------+---------------------------------------------| | D^ | Disable calling tone | |--------------+---------------------------------------------| | D; | Modem returned to idle state after dialing. | | | The semicolon can only be placed at the end | | | of the dial command. | +------------------------------------------------------------+ +------------------------------------------------------------+ | FACTORY DEFAULT PROFILE | |------------------------------------------------------------| | Type: | Configuration | |--------------+---------------------------------------------| | Format: | AT [cmds] &F [cmds] | |--------------+---------------------------------------------| | Description: | Sets values in active profile to values | | | found in the default profile | |--------------+---------------------------------------------| | Command | Function | |--------------+---------------------------------------------| | i &F0 | Restore factory configuration 0 | |--------------+---------------------------------------------| | &F1 | Restore factory configuration 1 | +------------------------------------------------------------+ +------------------------------------------------------------+ | FLOW CONTROL | |------------------------------------------------------------| | Type: | Configuration | |--------------+---------------------------------------------| | Format: | AT [cmds] &Kn [cmds] | |--------------+---------------------------------------------| | Description: | Enables flow control options | |--------------+---------------------------------------------| | Command | Function | |--------------+---------------------------------------------| | &K0 | Flow control disabled | |--------------+---------------------------------------------| | i &K3 | RTS/CTS flow control enabled | |--------------+---------------------------------------------| | &K4 | XON/XOFF flow control enabled | |--------------+---------------------------------------------| | &K5 | Transparent XON/XOFF flow control enabled | |--------------+---------------------------------------------| | &K6 | Both RTS/CTS and XON/XOFF flow control | | | enabled | +------------------------------------------------------------+ +------------------------------------------------------------+ | REPORT INFORMATION | |------------------------------------------------------------| | Type: | Immediate | |--------------+---------------------------------------------| | Format: | AT [cmds] In [cmds] | |--------------+---------------------------------------------| | Description: | Displays information requested | |--------------+---------------------------------------------| | Command | Function | |--------------+---------------------------------------------| | I0 | Reports the product identification code | |--------------+---------------------------------------------| | I1 | Reports ROM checksum | |--------------+---------------------------------------------| | I2 | Tests and reports ROM checksum | |--------------+---------------------------------------------| | I3 | Reports the firmware revision level | |--------------+---------------------------------------------| | I4 | Reports OEM defined identifier string | |--------------+---------------------------------------------| | I5 | Reports country code | |--------------+---------------------------------------------| | I6 | Reports modem data pump model | |--------------+---------------------------------------------| | I7 | Reports DAA code | +------------------------------------------------------------+ +------------------------------------------------------------+ | RTS/CTS | |------------------------------------------------------------| | Type: | Configuration | |--------------+---------------------------------------------| | Format: | AT [cmds] &Rn [cmds] | |--------------+---------------------------------------------| | Description: | Selects RTS/CTS options | |--------------+---------------------------------------------| | Command | Function | |--------------+---------------------------------------------| | i &R0 | Function not supported | |--------------+---------------------------------------------| | &R1 | CTS forced high, RTS is ignored. | +------------------------------------------------------------+ +------------------------------------------------------------+ | SPEAKER VOLUME | |------------------------------------------------------------| | Type: | Configuration | |--------------+---------------------------------------------| | Format: | AT [cmds] Ln [cmds] | |--------------+---------------------------------------------| | Description: | Controls speaker volume | |--------------+---------------------------------------------| | Command | Function | |--------------+---------------------------------------------| | L0 | Low volume setting | |--------------+---------------------------------------------| | L1 | Low volume setting | |--------------+---------------------------------------------| | i L2 | Medium volume setting | |--------------+---------------------------------------------| | L3 | Highest volume setting | +------------------------------------------------------------+ +------------------------------------------------------------+ | STORE TELEPHONE NUMBER | |------------------------------------------------------------| | Type: | Configuration | |--------------+---------------------------------------------| | Format: | AT [cmds] &Zn=(phone # & modifiers) | |--------------+---------------------------------------------| | Description: | Writes selected telephone numbers into the | | | non-volatile memory at location n | |------------------------------------------------------------| | Note: The characters described in the D command are | | valid for use in the &Z command; telephone numbers | | and modifiers can include up to 36 characters. | |------------------------------------------------------------| | Command | Function | |--------------+---------------------------------------------| | &Z0 | Stores a 34 digit dial string | |--------------+---------------------------------------------| | &Z1 | Stores a 34 digit dial string | |--------------+---------------------------------------------| | &Z2 | Stores a 34 digit dial string | |--------------+---------------------------------------------| | &Z3 | Stores a 34 digit dial string | +------------------------------------------------------------+ Extended AT Commands +------------------------------------------------------------+ | SINGLE LINE CONNECT MESSAGE | |------------------------------------------------------------| | Type: | Configuration | |--------------+---------------------------------------------| | Format: | AT [cmds] \Vn [cmds] | |--------------+---------------------------------------------| | Description: | Selects the operating mode the modem uses | | | while connected | |--------------+---------------------------------------------| | Command | Function | |--------------+---------------------------------------------| | \V0 | Connect messages are controlled by the | | | command settings X, W, and S95 | |--------------+---------------------------------------------| | \V1 | Connect messages are displayed in single | | | line format | +------------------------------------------------------------+ S(status) -REGISTERS +------------------------------------------------------------+ | AUTOSYNC OPTIONS | |------------------------------------------------------------| | Type: | Register | |--------------+---------------------------------------------| | Format | AT [cmds] S19=n [cmds] | |--------------+---------------------------------------------| | Default: | 0 | |--------------+---------------------------------------------| | Range: | 0-255 | |--------------+---------------------------------------------| | Unit: | 1 second | |--------------+---------------------------------------------| | Description: | Sets the AutoSync options | +------------------------------------------------------------+ +------------------------------------------------------------+ | CONNECTION FAILURE CODES | |------------------------------------------------------------| | Type: | Register | |--------------+---------------------------------------------| | Format | AT [cmds] S86? [cmds] | |--------------+---------------------------------------------| | Description: | Reports codes which correspond to the | | | possible causes of a connection failure | |--------------+---------------------------------------------| | Value | Meaning | |--------------+---------------------------------------------| | 0 | Normal hang up | |--------------+---------------------------------------------| | 4 | Carrier signal lost | |--------------+---------------------------------------------| | 5 | No error-control detected for remote modem | | | during feature negotiation | |--------------+---------------------------------------------| | 9 | No common protocol found | |--------------+---------------------------------------------| | 12 | No failure - remote modem disconnected | | | normally | |--------------+---------------------------------------------| | 13 | Remote modem failed to respond after 10 | | | re-transmissions same message | |--------------+---------------------------------------------| | 14 | Violation of negotiated protocol caused | | | failure | +------------------------------------------------------------+ +------------------------------------------------------------+ | DATA COMPRESSION CONTROL | |------------------------------------------------------------| | Type: | Register | |--------------+---------------------------------------------| | Format | AT [cmds] S46 [cmds] | |--------------+---------------------------------------------| | Default: | 128 | |--------------+---------------------------------------------| | Range: | 128 | |--------------+---------------------------------------------| | Description: | Controls data compression | +------------------------------------------------------------+ +------------------------------------------------------------+ | HDLC ADDRESS | |------------------------------------------------------------| | Type: | Register | |--------------+---------------------------------------------| | Format | AT [cmds] S20=n [cmds] | |--------------+---------------------------------------------| | Default: | 0 | |--------------+---------------------------------------------| | Range: | 0-255 | |--------------+---------------------------------------------| | Unit: | 1 second | |--------------+---------------------------------------------| | Description: | Sets the AutoSync HDLC address | +------------------------------------------------------------+ +------------------------------------------------------------+ | V.42 NEGOTIATION | |------------------------------------------------------------| | Type: | Register | |--------------+---------------------------------------------| | Format | AT [cmds] S48 [cmds] | |--------------+---------------------------------------------| | Default: | 7 | |--------------+---------------------------------------------| | Range: | 0, 7, 128 | |--------------+---------------------------------------------| | Description: | Controls V.42 negotiation | +------------------------------------------------------------+