MAXTECH CORPORATION =================== XPV 56I41 (K56PLUS-L/CPI-SVD) Card Type Modem, Fax Chip Set Lucent I/O Options Line in, line out, microphone in, speaker out Maximum Modem Rate 56Kbps Maximum Fax Rate 14.4Kbps Data Modulation Bell 103/212A Protocol ITU-T V.21, V.22, V.22bis, V.23, V.32, V.32bis, V.34, K56Plus Fax Modulation ITU-T V.17, V.29, V.27ter Protocol Error MNP5, V.42, V.42bis Correction/Compression Fax Class Class I & II Data Bus 16-bit ISA +------------------------------------------------------------+ | SUPPORTED COMMAND SET | |------------------------------------------------------------| | Basic AT Commands | |------------------------------------------------------------| | AT, '+++', A/ | |------------------------------------------------------------| | A, E, H, M, O, P, Q, T, V, W, Y, Z | |------------------------------------------------------------| | &C, &F, &G, &V, &W, &Z | |------------------------------------------------------------| | Extended AT Commands | |------------------------------------------------------------| | \A, \B, \J, \K, \T, \X | |------------------------------------------------------------| | -C | |------------------------------------------------------------| | S Registers | |------------------------------------------------------------| | S0, S1, S2, S3, S4, S5, S6, S7, S8, S9, S10, S11, S12, | | S14, S21, S22, S24, S30, S36, S37, S48 | |------------------------------------------------------------| | | |------------------------------------------------------------| | Note: See MHI Help File for full command documentation. | +------------------------------------------------------------+ Proprietary AT Command Set +------------------------------------------------------------+ | AUTOSCAN MODE | |------------------------------------------------------------| | Type: | Immediate | |--------------+---------------------------------------------| | Format: | AT [cmds] Nn [cmds] | |--------------+---------------------------------------------| | Description: | Enables/Disables Autoscan mode | |--------------+---------------------------------------------| | Command | Function | |--------------+---------------------------------------------| | N0 | Autoscan mode disabled | |--------------+---------------------------------------------| | i N1 | Autoscan mode enabled | +------------------------------------------------------------+ +------------------------------------------------------------+ | COMMUNICATIONS MODE (ASYNCHRONOUS) | |------------------------------------------------------------| | Type: | Configuration | |--------------+---------------------------------------------| | Format: | AT [cmds] &Mn [cmds] | |--------------+---------------------------------------------| | Description: | Selects communications mode | |--------------+---------------------------------------------| | Command | Mode | |--------------+---------------------------------------------| | i &M0 | Asynchronous mode | +------------------------------------------------------------+ +------------------------------------------------------------+ | COMMUNICATIONS MODE (DATA LINK AND FALLBACK) | |------------------------------------------------------------| | Type: | Configuration | |--------------+---------------------------------------------| | Format: | AT [cmds] &Q [cmds] | |--------------+---------------------------------------------| | Description: | Configures data link options | |--------------+---------------------------------------------| | Command | Function | |--------------+---------------------------------------------| | &Q0 | Set Direct data link only | |--------------+---------------------------------------------| | &Q5 | Set V.42 data link with fallback options | |--------------+---------------------------------------------| | &Q6 | Set Normal data link only | +------------------------------------------------------------+ +------------------------------------------------------------+ | COMMUNICATION PROTOCOLS | |------------------------------------------------------------| | Type: | Configuration | |--------------+---------------------------------------------| | Format: | AT [cmds] Bn [cmds] | |--------------+---------------------------------------------| | Description: | Selects the communication protocol for data | | | calls | |------------------------------------------------------------| | Note: The B command allows the simultaneous selection | | of more than one suffix, enabling multiple protocols. | |------------------------------------------------------------| | Command | Protocol | |--------------+---------------------------------------------| | B0 | Sets CCITT mode | |--------------+---------------------------------------------| | i B1 | Sets Bell mode | |--------------+---------------------------------------------| | B2 | CCITT V.23 originate: transmit 75/receive | | | 1200bps | |--------------+---------------------------------------------| | B3 | CCITT V.23 originate: transmit 1200/receive | | | 75bps | |--------------+---------------------------------------------| | B15 | Sets V.21 at 300 bps | |--------------+---------------------------------------------| | B16 | Sets Bell 103 at 300 bps | +------------------------------------------------------------+ +------------------------------------------------------------+ | DATA SET READY (DSR) | |------------------------------------------------------------| | Type: | Configuration | |--------------+---------------------------------------------| | Format: | AT [cmds] &Sn [cmds] | |--------------+---------------------------------------------| | Description: | Selects DSR options | |--------------+---------------------------------------------| | Command | Function | |--------------+---------------------------------------------| | &S0 | DSR forced high | |--------------+---------------------------------------------| | i &S1 | DSR is off while in command mode and set on | | | in on-line mode | +------------------------------------------------------------+ +------------------------------------------------------------+ | DATA TERMINAL READY (DTR) | |------------------------------------------------------------| | Type: | Configuration | |--------------+---------------------------------------------| | Format: | AT [cmds] &Dn [cmds] | |--------------+---------------------------------------------| | Description: | Selects modem response to DTR | |--------------+---------------------------------------------| | Command | Function | |--------------+---------------------------------------------| | i &D0 | Modem does not respond to DTR | |--------------+---------------------------------------------| | &D1 | Modem goes to command mode after DTR goes | | | is off | |--------------+---------------------------------------------| | &D2 | Modem goes to command mode and disconnects | | | (hangs up) after DTR goes off; Auto-Answer | | | is disabled. | |--------------+---------------------------------------------| | &D3 | Modem is initialized after DTR goes off | +------------------------------------------------------------+ +------------------------------------------------------------+ | DIAL | |------------------------------------------------------------| | Type: | Immediate | |--------------+---------------------------------------------| | Format: | AT [cmds] D<#> [cmds] | |--------------+---------------------------------------------| | Description: | Dials telephone number according to any | | | modifiers included in the string | |--------------+---------------------------------------------| | Note: | Any combination of modifiers can be used to | | | produce the desired dial functions in | | | sequence. | |--------------+---------------------------------------------| | Command | Function | |--------------+---------------------------------------------| | DL | Re-dial last number | |--------------+---------------------------------------------| | DP | Pulse dialing enabled | |--------------+---------------------------------------------| | i DT | Tone dialing enabled/Pulse dialing disabled | |--------------+---------------------------------------------| | DW | Dialing resumed following dial tone | | | detection | |--------------+---------------------------------------------| | D, | Dialing paused for amount of time specified | | | in S8 register | |--------------+---------------------------------------------| | D"WXY" | Optional method of denoting telephone | | | numbers. Letters enclosed in quotes are | | | interpreted as numbers according to the | | | system found on a telephone keypad. | |--------------+---------------------------------------------| | D! | Flash function initiated. Modem commanded | | | to go off-hook for specified time before | | | returning on-hook. | |--------------+---------------------------------------------| | D@ | Wait for Quite Answer function enabled. | | | Modem waits until a "quiet answer," a | | | ring-back signal followed by silence up to | | | the time specified in S7, is received prior | | | to executing the rest of the dial string. | |--------------+---------------------------------------------| | D; | Modem returned to idle state after dialing. | | | The semicolon can only be placed at the end | | | of the dial command. | +------------------------------------------------------------+ +------------------------------------------------------------+ | FLOW CONTROL | |------------------------------------------------------------| | Type: | Immediate | |--------------+---------------------------------------------| | Format: | AT [cmds] &K [cmds] | |--------------+---------------------------------------------| | Description: | Configures flow control settings | |--------------+---------------------------------------------| | Command | Function | |--------------+---------------------------------------------| | &K0 | Flow control disabled | |--------------+---------------------------------------------| | &K3 | RTS/CTS hardware flow control enabled | |--------------+---------------------------------------------| | &K4 | XON/XOFF software flow control enabled | |--------------+---------------------------------------------| | &K5 | Transparent XON/XOFF software flow control | | | enabled | |--------------+---------------------------------------------| | &K6 | RTS/CTS & XON/XOFF flow control enabled | +------------------------------------------------------------+ +------------------------------------------------------------+ | HAYES SMARTMODEM 300 COMPATIBILITY | |------------------------------------------------------------| | Type: | Configuration | |--------------+---------------------------------------------| | Format: | AT [cmds] Xn [cmds] | |--------------+---------------------------------------------| | Description: | Configures modem response and blind dialing | | | capabilities | |--------------+---------------------------------------------| | Command | Function | |--------------+---------------------------------------------| | X0 | Sets modem to use Hayes Smartmodem 300 | | | responses and blind dialing | |--------------+---------------------------------------------| | X1 | Sets modem to use Hayes Smartmodem 300 | | | responses, CONNECT responses, and blind | | | dialing | |--------------+---------------------------------------------| | X2 | Sets modem to use Hayes Smartmodem 300 | | | responses, CONNECT responses, dial tone | | | detection, and blind dialing | |--------------+---------------------------------------------| | X3 | Sets modem to use Hayes Smartmodem 300 | | | responses, CONNECT responses, busy | | | detection, and blind dialing | |--------------+---------------------------------------------| | i X4 | Set modem to use all responses, dial tone | | | detection, and busy signal detection | |--------------+---------------------------------------------| | X5 | Set modem to use all responses, dial tone | | | detection, and busy signal detection | |--------------+---------------------------------------------| | X6 | Set modem to use all responses, dial tone | | | detection, and busy signal detection | |--------------+---------------------------------------------| | X7 | Sets modem to use Hayes Smartmodem 300 | | | responses, dial tone detection, busy signal | | | detection, and blind dialing | +------------------------------------------------------------+ +------------------------------------------------------------+ | LINE TYPE | |------------------------------------------------------------| | Type: | Configuration | |--------------+---------------------------------------------| | Format: | AT [cmds] &Ln [cmds] | |--------------+---------------------------------------------| | Description: | Selects line type | |--------------+---------------------------------------------| | Command | Line Type | |--------------+---------------------------------------------| | i &L0 | Switched line (PSTN/Dial-up) | |------------------------------------------------------------| | REPORT INFORMATION | |------------------------------------------------------------| | Type: | Immediate | |--------------+---------------------------------------------| | Format: | AT [cmds] In [cmds] | |--------------+---------------------------------------------| | Description: | Displays information requested | |--------------+---------------------------------------------| | Command | Function | |--------------+---------------------------------------------| | I0 | Reports modem model and speed | |--------------+---------------------------------------------| | I1 | Reports ROM checksum | |--------------+---------------------------------------------| | I2 | Tests and reports internal memory | |--------------+---------------------------------------------| | I3 | Reports default speed and modem model | |--------------+---------------------------------------------| | I4 | Reports firmware ID | |--------------+---------------------------------------------| | I9 | Reports country ID | +------------------------------------------------------------+ +------------------------------------------------------------+ | RESTORE PROFILE ON POWER-UP | |------------------------------------------------------------| | Type: | Configuration | |--------------+---------------------------------------------| | Format: | AT [cmds] &Yn [cmds] | |--------------+---------------------------------------------| | Description: | Restores a selected profile into the active | | | profile on power-up (hard reset) | |--------------+---------------------------------------------| | Command | Function | |--------------+---------------------------------------------| | i &Y0 | Restore profile 0 on power-up | +------------------------------------------------------------+ +------------------------------------------------------------+ | SPEAKER VOLUME | |------------------------------------------------------------| | Type: | Configuration | |--------------+---------------------------------------------| | Format: | AT [cmds] Ln [cmds] | |--------------+---------------------------------------------| | Description: | Controls speaker volume | |--------------+---------------------------------------------| | Command | Function | |--------------+---------------------------------------------| | L0 | Low volume setting | |--------------+---------------------------------------------| | i L1 | Low volume setting | |--------------+---------------------------------------------| | L2 | Medium volume setting | |--------------+---------------------------------------------| | L3 | Highest volume setting | +------------------------------------------------------------+ +------------------------------------------------------------+ | TEST MODES | |------------------------------------------------------------| | Type: | Immediate | |--------------+---------------------------------------------| | Format: | AT [cmds] &Tn | |--------------+---------------------------------------------| | Description: | Selects test options | |--------------+---------------------------------------------| | Command | Function | |--------------+---------------------------------------------| | &T0 | End current test | |--------------+---------------------------------------------| | &T1 | Begin local analog loopback test | |--------------+---------------------------------------------| | &T3 | Begin local digital loopback test | |--------------+---------------------------------------------| | &T6 | Begin remote digital loopback test | +------------------------------------------------------------+ Extended AT Commands +------------------------------------------------------------+ | AUTO-RETRAIN - AUTO-FALLBACK/FALL-FORWARD | |------------------------------------------------------------| | Type: | Configuration | |--------------+---------------------------------------------| | Format: | AT [cmds] %En [cmds] | |--------------+---------------------------------------------| | Description: | Controls auto-retrain mode and | | | fallback/fall-forward | |--------------+---------------------------------------------| | Command | Function | |--------------+---------------------------------------------| | %E0 | Auto-retrain disabled | |--------------+---------------------------------------------| | %E1 | Auto-retrain enabled | +------------------------------------------------------------+ +------------------------------------------------------------+ | COMPRESSION | |------------------------------------------------------------| | Type: | Configuration | |--------------+---------------------------------------------| | Format: | AT [cmds] %Cn [cmds] | |--------------+---------------------------------------------| | Description: | Selects data compression | |--------------+---------------------------------------------| | Command | Function | |--------------+---------------------------------------------| | %C0 | Data compression disabled | |--------------+---------------------------------------------| | %C1 | MNP5 and V.42bis; or data compression and | | | correction enabled | +------------------------------------------------------------+ +------------------------------------------------------------+ | CONNECT MODE | |------------------------------------------------------------| | Type: | Configuration | |--------------+---------------------------------------------| | Format: | AT [cmds] \Nn [cmds] | |--------------+---------------------------------------------| | Description: | Controls the type of connection the modem | | | will operate in | |--------------+---------------------------------------------| | Command | Function | |--------------+---------------------------------------------| | \N0 | Enables Normal mode | |--------------+---------------------------------------------| | \N1 | Enables Direct mode | |--------------+---------------------------------------------| | \N2 | Enables MNP mode | |--------------+---------------------------------------------| | i \N3 | Enables V.42/MNP/Normal modes | |--------------+---------------------------------------------| | \N4 | Enables V.42 mode | |--------------+---------------------------------------------| | \N5 | Enables V.42/MNP/Normal modes | |--------------+---------------------------------------------| | \N7 | Enables V.42/MNP/Normal modes | +------------------------------------------------------------+ +------------------------------------------------------------+ | ERROR CORRECTION | |------------------------------------------------------------| | Type: | Immediate | |--------------+---------------------------------------------| | Format: | AT [cmds] \Vn [cmds] | |--------------+---------------------------------------------| | Description: | Reports error correction result codes | |--------------+---------------------------------------------| | Command | Function | |--------------+---------------------------------------------| | \V0 | Error correction result codes disabled | |--------------+---------------------------------------------| | i \V1 | Error correction result codes enabled | |--------------+---------------------------------------------| | \V2 | Error correction result codes enabled | +------------------------------------------------------------+ +------------------------------------------------------------+ | FLOW CONTROL TYPE | |------------------------------------------------------------| | Type: | Configuration | |--------------+---------------------------------------------| | Format: | AT [cmds] \Qn [cmds] | |--------------+---------------------------------------------| | Description: | Sets type of flow control used by modem | |--------------+---------------------------------------------| | Command | Function | |--------------+---------------------------------------------| | \Q0 | Flow control disabled | |--------------+---------------------------------------------| | \Q1 | Bi-Directional XON/XOFF flow control | | | enabled | |--------------+---------------------------------------------| | \Q3 | Bi-Directional RTS/CTS flow control enabled | +------------------------------------------------------------+ +------------------------------------------------------------+ | RE-DIALING SUPPRESSION | |------------------------------------------------------------| | Type: | Configuration | |--------------+---------------------------------------------| | Format: | AT [cmds] %Xn [cmds] | |--------------+---------------------------------------------| | Description: | Configures re-dialing suppression settings | |--------------+---------------------------------------------| | Command | Function | |--------------+---------------------------------------------| | i %X0 | Re-dialing suppression disabled | |--------------+---------------------------------------------| | %X1 | Re-dialing suppression enabled | +------------------------------------------------------------+ S(status) -Registers +------------------------------------------------------------+ | DATA CALLING TONE | |------------------------------------------------------------| | Type: | Register | |--------------+---------------------------------------------| | Format | AT [cmds] S35=n [cmds] | |--------------+---------------------------------------------| | Default: | 0 | |--------------+---------------------------------------------| | Range: | 0, 1 | |--------------+---------------------------------------------| | Unit: | Unidentified | |--------------+---------------------------------------------| | Description: | Enables the data calling tone | +------------------------------------------------------------+ +------------------------------------------------------------+ | DIAL LINE RATE | |------------------------------------------------------------| | Type: | Register | |--------------+---------------------------------------------| | Format | AT [cmds] S38=n [cmds] | |--------------+---------------------------------------------| | Default: | 0 | |--------------+---------------------------------------------| | Range: | 0 - 19 | |--------------+---------------------------------------------| | Unit: | Unidentified | |--------------+---------------------------------------------| | Description: | Sets the 56K dialing rate | +------------------------------------------------------------+ +------------------------------------------------------------+ | LOCAL PHONE STATUS | |------------------------------------------------------------| | Type: | Register | |--------------+---------------------------------------------| | Format | AT [cmds] S90=n [cmds] | |--------------+---------------------------------------------| | Default: | Unidentified | |--------------+---------------------------------------------| | Range: | 0, 1 | |--------------+---------------------------------------------| | Unit: | Unidentified | |--------------+---------------------------------------------| | Description: | 0=on hook, 1=off hook | +------------------------------------------------------------+ +------------------------------------------------------------+ | SLEEP MODE TIMER | |------------------------------------------------------------| | Type: | Register | |--------------+---------------------------------------------| | Format | AT [cmds] S89=n [cmds] | |--------------+---------------------------------------------| | Default: | 10 | |--------------+---------------------------------------------| | Range: | 0, 5 - 255 | |--------------+---------------------------------------------| | Unit: | seconds | |--------------+---------------------------------------------| | Description: | Sets the sleep mode timer | +------------------------------------------------------------+ +------------------------------------------------------------+ | SYNTHETIC RING DIALING | |------------------------------------------------------------| | Type: | Register | |--------------+---------------------------------------------| | Format | AT [cmds] S32=n [cmds] | |--------------+---------------------------------------------| | Default: | 10 | |--------------+---------------------------------------------| | Range: | Unidentified | |--------------+---------------------------------------------| | Unit: | dB | |--------------+---------------------------------------------| | Description: | Sets the volume of the synthetic ring | +------------------------------------------------------------+ +------------------------------------------------------------+ | SYNTHETIC RING FREQUENCY | |------------------------------------------------------------| | Type: | Register | |--------------+---------------------------------------------| | Format | AT [cmds] S33=n [cmds] | |--------------+---------------------------------------------| | Default: | 0 | |--------------+---------------------------------------------| | Range: | 0 - 5 | |--------------+---------------------------------------------| | Unit: | Unidentified | |--------------+---------------------------------------------| | Description: | Sets the value of the synthetic frequency | +------------------------------------------------------------+ +------------------------------------------------------------+ | TRANSMIT LEVEL | |------------------------------------------------------------| | Type: | Register | |--------------+---------------------------------------------| | Format | AT [cmds] S92=n [cmds] | |--------------+---------------------------------------------| | Default: | 15 | |--------------+---------------------------------------------| | Range: | 6 - 15 | |--------------+---------------------------------------------| | Unit: | dB | |--------------+---------------------------------------------| | Description: | Sets the transmission level volume | +------------------------------------------------------------+ +------------------------------------------------------------+ | V.34 MODUALTION | |------------------------------------------------------------| | Type: | Register | |--------------+---------------------------------------------| | Format | AT [cmds] S28=n [cmds] | |--------------+---------------------------------------------| | Default: | 1 | |--------------+---------------------------------------------| | Range: | 0 - 255 | |--------------+---------------------------------------------| | Description: | Enables V.34 modulation |