PURETEK INDUSTRIAL CO, INC. =========================== 14400BPS FAX/MODEM ADAPTER WITH VOICE Card Type Fax, Modem (asynchronous), Voice Chip Set Unidentified I/O Options Speakerphone, Voicemail Maximum Data Rate 14.4Kbps Maximum Fax Rate 14.4Kbps Data Bus 8-bit ISA Fax Class Class II Data Modulation Bell 103/212A Protocol ITU-T V.21, V.22, V.22bis, V.23, V.32, V.32bis Fax Modulation ITU-T V.17, V.21CH2, V.27ter, V.29 Protocol Error MNP5, V.42, V.42bis Correction/Compression +------------------------------------------------------------+ | CONNECTIONS | |------------------------------------------------------------| | Function | Label | Function | Label | |------------------------------------------------------------| | Line out | CN1 | Microphone connection | CN3 | |------------------+----------+-----------------------+------| | Line in | CN2 | Speaker connection | CN4 | +------------------------------------------------------------+ +------------------------------------------------------------+ | SERIAL PORT ADDRESS | |------------------------------------------------------------| | Setting | J1 | J2 | J3 | |---------------+--------------+--------------+--------------| | COM1 (3F8h) | Open | Open | Open | |---------------+--------------+--------------+--------------| | COM2 (2F8h) | Closed | Open | Open | |---------------+--------------+--------------+--------------| | COM3 (3E8h) | Open | Closed | Open | |---------------+--------------+--------------+--------------| | COM4 (2E8h) | Closed | Closed | Open | |---------------+--------------+--------------+--------------| | COM5 | Open | Open | Closed | |---------------+--------------+--------------+--------------| | COM6 | Closed | Open | Closed | |---------------+--------------+--------------+--------------| | COM7 | Open | Closed | Closed | |---------------+--------------+--------------+--------------| | COM8 | Closed | Closed | Closed | +------------------------------------------------------------+ +------------------------------------------------------------+ | INTERRUPT SELECTION | |------------------------------------------------------------| | Setting | J4 | J5 | J6 | J7 | J8 | |----------+---------+---------+---------+---------+---------| | 2 | Closed | Open | Open | Open | Open | |----------+---------+---------+---------+---------+---------| | 3 | Open | Closed | Open | Open | Open | |----------+---------+---------+---------+---------+---------| | 4 | Open | Open | Closed | Open | Open | |----------+---------+---------+---------+---------+---------| | 5 | Open | Open | Open | Closed | Open | |----------+---------+---------+---------+---------+---------| | 9 | Open | Open | Open | Open | Closed | +------------------------------------------------------------+ +------------------------------------------------------------+ | SUPPORTED COMMAND SET | |------------------------------------------------------------| | Basic AT Commands | |------------------------------------------------------------| | AT, '+++', 'Comma', A/ | |------------------------------------------------------------| | A, B, D, E, H, L, M, O, Q, S, V, X, Y, Z | |------------------------------------------------------------| | &C, &D, &F, &G, &J, &K, &M, &P, &R, &S, &T, &V, &W, &X, | | &Y, &Z | |------------------------------------------------------------| | Extended AT Commands | |------------------------------------------------------------| | \A, \B, \E, \J, \K, \L, \O, \U, \V, \X, %A | |------------------------------------------------------------| | S Registers | |------------------------------------------------------------| | S0, S1, S2, S3, S4, S5, S6, S7, S8, S9, S10, S11, S12, | | S14, S16, S18, S21, S22, S25 | |------------------------------------------------------------| | S26, S27, S36, S46, S82, S95 | |------------------------------------------------------------| | Note: Please see MHI Help file for full command | | documentation. | +------------------------------------------------------------+ Proprietary AT Command Set +------------------------------------------------------------+ | BIT-MAPPED REGISTER S23 | |------------------------------------------------------------| | Format | AT [cmds] S23=n [cmds] | |--------------+---------------------------------------------| | Default: | 28 | |--------------+---------------------------------------------| | Range: | 0-191 | |--------------+---------------------------------------------| | Unit: | Bit-mapped | |--------------+---------------------------------------------| | Description: | Grants/denies remote digital loopback, | | | controls DTE rate and parity, and sets | | | guard tone. | |--------------+---------------------------------------------| | Bit | Value | Function | |------+-------+---------------------------------------------| | 0 | i 0 | Remote digital loopback denied | | | | | | | 1 | Remote digital loopback allowed | |------+-------+---------------------------------------------| | 3 - | 000 | Sets serial port speed to 0-300bps | | 1 | | | | | 001 | Sets serial port speed to 600bps | | | | | | | 010 | Sets serial port speed to 1200bps | | | | | | | 011 | Sets serial port speed to 2400bps | | | | | | | 100 | Sets serial port speed to 4800bps | | | | | | | 101 | Sets serial port speed to 9600bps | | | | | | | i 110 | Sets serial port speed to 19200bps | | | | | | | 111 | Sets serial port speed to 48400bps or upper | | | | data rate | |------+-------+---------------------------------------------| | 5, 4 | 00 | Parity even | | | | | | | i 01 | Space Parity | | | | | | | 10 | Parity odd | | | | | | | 11 | Mark or No Parity | |------+-------+---------------------------------------------| | 7, 6 | i 00 | Guard tone disabled | | | | | | | 01 | Guard tone 550Hz enabled | | | | | | | 10 | Guard tone 1800Hz enabled | +------------------------------------------------------------+ +------------------------------------------------------------+ | BIT SAMPLING | |------------------------------------------------------------| | Type: | Configuration | |--------------+---------------------------------------------| | Format: | AT [cmds] #VBS=n [cmds] | |--------------+---------------------------------------------| | Description: | Select bit sampling | |------------------------------------------------------------| | Command | Function | |----------------+-------------------------------------------| | #VBS? | Returns current setting of #VBS command | |----------------+-------------------------------------------| | #VBS=2 | 2 bits per sample ADPCM enabled | |----------------+-------------------------------------------| | #VBS=3 | 3 bits per sample ADPCM enabled | |----------------+-------------------------------------------| | #VBS=4 | 4 bits per sample ADPCM enabled | +------------------------------------------------------------+ +------------------------------------------------------------+ | BREAK TYPE | |------------------------------------------------------------| | Type: | Configuration | |--------------+---------------------------------------------| | Format: | AT [cmds] \Kn [cmds] | |--------------+---------------------------------------------| | Description: | Configures action of break signal | |------------------------------------------------------------| | Command | Function | |-----------+------------------------------------------------| | \K0 | Online command mode enabled, send no break to | | | remote modem | |-----------+------------------------------------------------| | \K1 | Break sent to remote modem and buffers cleared | |-----------+------------------------------------------------| | \K2 | Online command mode enabled, send no break to | | | remote modem | |-----------+------------------------------------------------| | \K3 | Send break to remote modem immediately | |-----------+------------------------------------------------| | \K4 | Online command mode enabled, send no break to | | | remote modem | |-----------+------------------------------------------------| | i \K5 | Send break with transmitted data | +------------------------------------------------------------+ +------------------------------------------------------------+ | COMPRESSION | |------------------------------------------------------------| | Type: | Configuration | |--------------+---------------------------------------------| | Format: | AT [cmds] %Cn [cmds] | |--------------+---------------------------------------------| | Description: | Selects data compression | |--------------+---------------------------------------------| | Command | Function | |--------------+---------------------------------------------| | %C0 | Data compression disabled | |--------------+---------------------------------------------| | %C1 | Data compression enabled | +------------------------------------------------------------+ +------------------------------------------------------------+ | CONNECT MODE | |------------------------------------------------------------| | Type: | Configuration | |--------------+---------------------------------------------| | Format: | AT [cmds] \Nn [cmds] | |--------------+---------------------------------------------| | Description: | Controls the type of connection the modem | | | will operate in | |--------------+---------------------------------------------| | Command | Function | |--------------+---------------------------------------------| | \N0 | Normal mode enabled | |--------------+---------------------------------------------| | \N1 | Direct mode enabled | |--------------+---------------------------------------------| | \N2 | MNP Reliable mode enabled | |--------------+---------------------------------------------| | \N3 | MNP auto-reliable mode enabled | |--------------+---------------------------------------------| | \N4 | V.42 reliable mode with phase detection | | | enabled | |--------------+---------------------------------------------| | i \N5 | V.42 auto-reliable mode with phase | | | detection enabled | |--------------+---------------------------------------------| | \N6 | V.42 reliable mode without phase detection | | | enabled | |--------------+---------------------------------------------| | \N7 | V.42 auto-reliable mode without phase | | | detection enabled | +------------------------------------------------------------+ +------------------------------------------------------------+ | DIAL - STORED NUMBER | |------------------------------------------------------------| | Type: | Immediate | |--------------+---------------------------------------------| | Format: | AT [cmds] DS=n [cmds] | |--------------+---------------------------------------------| | Description: | Dial stored number from memory location n, | | | (n=0-2) | +------------------------------------------------------------+ +------------------------------------------------------------+ | DIAL/BUSY TONE DETECT RANGE | |------------------------------------------------------------| | Type: | Register | |--------------+---------------------------------------------| | Format: | AT [cmds] S96=n [cmds] | |--------------+---------------------------------------------| | Description: | Selects the range the modem uses for | | | dial/busy tone detection | |------------------------------------------------------------| | Command | Range | Function | |---------------+--------------+-----------------------------| | i S96=0 | 350 - 620Hz | USA, Korea, Taiwan | |---------------+--------------+-----------------------------| | S96=1 | 425 - 450Hz | Belgium | |---------------+--------------+-----------------------------| | S96=2 | 440 - 700Hz | France | |---------------+--------------+-----------------------------| | S96=3 | 350 - 450Hz | Israel, Japan | |---------------+--------------+-----------------------------| | S96=4 | 375 - 475Hz | Italy, Norway, Germany, | | | | Denmark | |---------------+--------------+-----------------------------| | S96=5 | 150 - 450Hz | Netherlands | |---------------+--------------+-----------------------------| | S96=6 | 270 - 320Hz | Singapore | |---------------+--------------+-----------------------------| | S96=7 | 350 - 500Hz | Sweden | |---------------+--------------+-----------------------------| | S96=8 | 375 - 550Hz | Switzerland | |---------------+--------------+-----------------------------| | S96=9 | 350 - 440Hz | United Kingdom | |---------------+--------------+-----------------------------| | S96=10 | 110 - 700Hz | Full range | +------------------------------------------------------------+ +------------------------------------------------------------+ | ENERGY DETECTION THRESHOLD | |------------------------------------------------------------| | Type: | Register | |--------------+---------------------------------------------| | Format: | AT [cmds] S97=n [cmds] | |--------------+---------------------------------------------| | Default: | 45 | |--------------+---------------------------------------------| | Range: | Unidentified | |--------------+---------------------------------------------| | Unit: | Unidentified | |--------------+---------------------------------------------| | Description: | Selects dial tone detect threshold during | | | CPM mode | +------------------------------------------------------------+ +------------------------------------------------------------+ | EXTENDED RESULT CODES | |------------------------------------------------------------| | Type: | Configuration | |--------------+---------------------------------------------| | Format: | AT [cmds] Wn [cmds] | |--------------+---------------------------------------------| | Description: | Controls extended result codes | |--------------+---------------------------------------------| | Command | Function | |--------------+---------------------------------------------| | i W0 | V.42 extended result codes disabled | |--------------+---------------------------------------------| | W1 | V.42 extended result codes enabled | +------------------------------------------------------------+ +------------------------------------------------------------+ | FLOW CONTROL TYPE | |------------------------------------------------------------| | Type: | Configuration | |--------------+---------------------------------------------| | Format: | AT [cmds] \Qn [cmds] | |--------------+---------------------------------------------| | Description: | Sets type of flow control used by modem | |--------------+---------------------------------------------| | Command | Function | |--------------+---------------------------------------------| | \Q0 | Flow control disabled | |--------------+---------------------------------------------| | \Q1 | XON/XOFF software flow control enabled | |--------------+---------------------------------------------| | \Q2 | CTS hardware flow control enabled | |--------------+---------------------------------------------| | i \Q3 | RTS/CTS hardware flow control enabled | +------------------------------------------------------------+ +------------------------------------------------------------+ | INACTIVITY TIMER | |------------------------------------------------------------| | Type: | Configuration | |--------------+---------------------------------------------| | Format: | AT [cmds] \Tn [cmds] | |--------------+---------------------------------------------| | Default: | 0 | |--------------+---------------------------------------------| | Range: | 0-90 | |--------------+---------------------------------------------| | Unit: | 1 minute | |--------------+---------------------------------------------| | Description: | Sets the length of time that the modem does | | | not receive information before it | | | disconnects. | +------------------------------------------------------------+ +------------------------------------------------------------+ | LINE TYPE | |------------------------------------------------------------| | Type: | Configuration | |--------------+---------------------------------------------| | Format: | AT [cmds] &Ln [cmds] | |--------------+---------------------------------------------| | Description: | Selects line type | |--------------+---------------------------------------------| | Command | Line Type | |--------------+---------------------------------------------| | i &L0 | Switched line | |--------------+---------------------------------------------| | &L1 | Leased-line - 2-wire | |--------------+---------------------------------------------| | &L2 | Leased-line - 4-wire | +------------------------------------------------------------+ +------------------------------------------------------------+ | MODE SELECTION | |------------------------------------------------------------| | Type: | Configuration | |--------------+---------------------------------------------| | Format: | AT [cmds] #CLS=n [cmds] | |--------------+---------------------------------------------| | Description: | Controls the mode the modem will operate in | |------------------------------------------------------------| | Command | Function | |-----------------+------------------------------------------| | #CLS? | Returns current setting of #CLS command | |-----------------+------------------------------------------| | #CLS=0 | Data mode enabled | |-----------------+------------------------------------------| | #CLS=2 | Fax class 2 command mode enabled | |-----------------+------------------------------------------| | #CLS=8 | Voice mode enabled | +------------------------------------------------------------+ +------------------------------------------------------------+ | MODEM MANUFACTURER | |------------------------------------------------------------| | Type: | Immediate | |--------------+---------------------------------------------| | Format: | AT [cmds] #MFR? [cmds] | |--------------+---------------------------------------------| | Description: | Reports modem manufacturer | +------------------------------------------------------------+ +------------------------------------------------------------+ | MODEM MODEL | |------------------------------------------------------------| | Type: | Immediate | |--------------+---------------------------------------------| | Format: | AT [cmds] #MDL? [cmds] | |--------------+---------------------------------------------| | Description: | Reports modem models | +------------------------------------------------------------+ +------------------------------------------------------------+ | MODEM REVISION | |------------------------------------------------------------| | Type: | Immediate | |--------------+---------------------------------------------| | Format: | AT [cmds] #REV? [cmds] | |--------------+---------------------------------------------| | Description: | Reports modem revision | +------------------------------------------------------------+ +------------------------------------------------------------+ | REPORT INFORMATION | |------------------------------------------------------------| | Type: | Immediate | |--------------+---------------------------------------------| | Format: | AT [cmds] In [cmds] | |--------------+---------------------------------------------| | Description: | Displays information requested | |--------------+---------------------------------------------| | Command | Function | |--------------+---------------------------------------------| | I0 | Reports product-identification code | |--------------+---------------------------------------------| | I1 | Reports factory code | |--------------+---------------------------------------------| | I2 | Reports internal memory test | |--------------+---------------------------------------------| | I3 | Reports firmware version 1 | |--------------+---------------------------------------------| | I4 | Reports firmware version 2 | +------------------------------------------------------------+ +------------------------------------------------------------+ | SIGNAL ROUTING | |------------------------------------------------------------| | Type: | Configuration | |--------------+---------------------------------------------| | Format: | AT [cmds] #VLS=n [cmds] | |--------------+---------------------------------------------| | Description: | Select which signal is routed through the | | | modem | |------------------------------------------------------------| | Command | Function | |---------------+--------------------------------------------| | #VLS? | Returns current setting of #VLS command | |---------------+--------------------------------------------| | #VLS=0 | Phone line interface routed through the | | | modem | |---------------+--------------------------------------------| | #VLS=1 | Handset routed through the modem | |---------------+--------------------------------------------| | #VLS=2 | External speaker routed through the modem | |---------------+--------------------------------------------| | #VLS=3 | Auxiliary input device routed through the | | | modem | |---------------+--------------------------------------------| | #VLS=4 | Internal speaker routed through the modem | +------------------------------------------------------------+ +------------------------------------------------------------+ | SPEED - AUTOBAUD | |------------------------------------------------------------| | Type: | Configuration | |--------------+---------------------------------------------| | Format: | AT [cmds] #BDR=n [cmds] | |--------------+---------------------------------------------| | Description: | Controls speed | |------------------------------------------------------------| | Command | Function | |---------------+--------------------------------------------| | #BDR? | Returns current setting of #BDR command | |---------------+--------------------------------------------| | #BDR=0 | Autobaud detection enabled | |---------------+--------------------------------------------| | #BDR=n | Returns 'OK' and switches to new speed | | | specified by n*2400bps (n=1,2,4,6,8,16,24) | +------------------------------------------------------------+ +------------------------------------------------------------+ | TONE GENERATION | |------------------------------------------------------------| | Type: | Configuration | |--------------+---------------------------------------------| | Format: | AT [cmds] #VBT=n [cmds] | |--------------+---------------------------------------------| | Default: | Unidentified | |--------------+---------------------------------------------| | Range: | 1-40 | |--------------+---------------------------------------------| | Unit: | .1 second | |--------------+---------------------------------------------| | Description: | Controls the amount of time a tone is | | | generated | |--------------+---------------------------------------------| | Command | Function | |--------------+---------------------------------------------| | #VBT? | Returns current setting of #VBT command | +------------------------------------------------------------+ +------------------------------------------------------------+ | VOICE COMPRESSION METHOD | |------------------------------------------------------------| | Type: | Immediate | |--------------+---------------------------------------------| | Format: | AT [cmds] #VCI? [cmds] | |--------------+---------------------------------------------| | Description: | Reports voice compression method used | +------------------------------------------------------------+ +------------------------------------------------------------+ | VOICE INACTIVITY TIMER | |------------------------------------------------------------| | Type: | Register | |--------------+---------------------------------------------| | Format | AT [cmds] S30=n [cmds] | |--------------+---------------------------------------------| | Default: | 0 | |--------------+---------------------------------------------| | Range: | 0-255 | |--------------+---------------------------------------------| | Unit: | 1 second | |--------------+---------------------------------------------| | Description: | Maximum duration of DTE and DCE inactivity | | | allowed prior to initiating hang-up | | | process. | |--------------+---------------------------------------------| | Note: | S30=0 disables the timer and allows | | | indefinite inactivity. | +------------------------------------------------------------+ +------------------------------------------------------------+ | VOICE RECEIVE | |------------------------------------------------------------| | Type: | Immediate | |--------------+---------------------------------------------| | Format: | AT [cmds] #VTX [cmds] | |--------------+---------------------------------------------| | Description: | Enables voice receive during voice command | | | mode | +------------------------------------------------------------+ +------------------------------------------------------------+ | VOICE TRANSMIT | |------------------------------------------------------------| | Type: | Immediate | |--------------+---------------------------------------------| | Format: | AT [cmds] #VTX [cmds] | |--------------+---------------------------------------------| | Description: | Enables voice transmission during voice | | | command mode | +------------------------------------------------------------+ V.25bis COMMAND SET +------------------------------------------------------------+ | CALL REQUESTED NUMBER | |------------------------------------------------------------| | Type: | Immediate | |--------------+---------------------------------------------| | Format: | CRN<#> | |--------------+---------------------------------------------| | Description: | Dials the number given; it will ignore | | | spaces and hyphens in the string. | +------------------------------------------------------------+ +------------------------------------------------------------+ | CALL REQUEST WITH ADDRESS | |------------------------------------------------------------| | Type: | Immediate | |--------------+---------------------------------------------| | Format: | CRSn | |--------------+---------------------------------------------| | Description: | Dials the number stored in NVRAM at | | | location n | +------------------------------------------------------------+ +------------------------------------------------------------+ | PROGRAM NUMBER | |------------------------------------------------------------| | Type: | Configuration | |--------------+---------------------------------------------| | Format: | PRNn;<#> | |--------------+---------------------------------------------| | Description: | Stores a phone number in NVRAM at location | | | n | +------------------------------------------------------------+ +------------------------------------------------------------+ | REQUEST LISTED NUMBERS | |------------------------------------------------------------| | Type: | Immediate | |--------------+---------------------------------------------| | Format: | RLN | |--------------+---------------------------------------------| | Description: | Requests the modem to return the list of | | | stored numbers in NVRAM | +------------------------------------------------------------+ +------------------------------------------------------------+ | DISREGARD INCOMING CALL | |------------------------------------------------------------| | Type: | Immediate | |--------------+---------------------------------------------| | Format: | DIC | |--------------+---------------------------------------------| | Description: | Instructs the modem to ignore the incoming | | | call, if the modem is set to automatically | | | answer. | +------------------------------------------------------------+ +------------------------------------------------------------+ | CONNECT INCOMING CALLS | |------------------------------------------------------------| | Type: | Immediate | |--------------+---------------------------------------------| | Format: | CID | |--------------+---------------------------------------------| | Description: | Instructs the modem to answer an incoming | | | call. | +------------------------------------------------------------+ +------------------------------------------------------------+ | V.25bis/AT COMMANDS | |------------------------------------------------------------| | Type: | Immediate | |--------------+---------------------------------------------| | Format: | AT [cmds] ATC [cmds] | |--------------+---------------------------------------------| | Description: | Toggles between V.25bis and AT command set | +------------------------------------------------------------+