TEXT View Source
# PURE DATA, LTD.
PDI8023-16CAT
NIC Type Ethernet
Transfer Rate 10Mbps
Data Bus 16-bit ISA
Topology Star
Linear bus
Wiring Type Unshielded twisted pair
RG58A/U 50ohm coaxial
AUI transceiver via DB-15 port
Boot ROM Available
IMG IMG 1
+------------------------------------------------------------+
| SOFTWARE CONFIGURATION RESET |
|------------------------------------------------------------|
| Setting | E1 |
|---------------------------------+--------------------------|
| » | Normal operation | Pins 2 & 3 closed |
|--------+------------------------+--------------------------|
| | Reset | Pins 1 & 2 closed |
|------------------------------------------------------------|
| Note:Many of the options are configured using the setup |
| utility provided with the card. To reset those |
| configurations to the factory defaults, move E1 to the |
| Reset position (pins 1 & 2 closed) and apply power for a |
| few seconds. Always make sure that you turn off the power |
| to the computer before you change any jumpers. |
+------------------------------------------------------------+
+------------------------------------------------------------+
| CARD I/D NUMBER |
|------------------------------------------------------------|
| Number | E2A | E2B | E2C | E2D |
|-------------+-------------+----------+----------+----------|
| » | 1 | Open | Open | Open | Closed |
|------+------+-------------+----------+----------+----------|
| | 2 | Open | Open | Closed | Open |
|------+------+-------------+----------+----------+----------|
| | 3 | Open | Closed | Open | Open |
|------+------+-------------+----------+----------+----------|
| | 4 | Closed | Open | Open | Open |
|------------------------------------------------------------|
| Note:Up to four cards can be installed into a system at |
| the same time. |
| |
| If more than one card is installed each one must have a |
| seperate card I/D number. |
+------------------------------------------------------------+
+------------------------------------------------------------+
| LINK INTEGRITY TEST |
|------------------------------------------------------------|
| Setting | E3 |
|-------------------------------+----------------------------|
| » | Enabled | Pins 1 & 2 closed |
|-----------+-------------------+----------------------------|
| | Disabled | Pins 2 & 3 closed |
|------------------------------------------------------------|
| Note:The link integrity test is only valid when the cable |
| type is unshielded twisted pair. |
+------------------------------------------------------------+
+------------------------------------------------------------+
| CABLE TYPE |
|------------------------------------------------------------|
| Type | E5A | E5B | E5C | Isolation |
| | | | | Transformer |
| | | | | Location |
|-------------------+--------+--------+--------+-------------|
| » | RG58A/U | Open | Closed | Open | T3 |
| | 50ohm | | | | |
| | coaxial | | | | |
|----+--------------+--------+--------+--------+-------------|
| | Unshielded | Open | Open | Closed | N/A |
| | twisted pair | | | | |
|----+--------------+--------+--------+--------+-------------|
| | AUI | Closed | Open | Open | T2 |
| | transceiver | | | | |
| | via DB-15 | | | | |
| | port | | | | |
|------------------------------------------------------------|
| Note:If you leave E5B closed you can select the cable type |
| through the software setup utility included with the card. |
| However, you must still move the Isolation transformer to |
| the appropriate socket. |
+------------------------------------------------------------+
+------------------------------------------------------------+
| SEGMENT LENGTH |
|------------------------------------------------------------|
| Maximum Length | JP7 |
|--------------------------------+---------------------------|
| » | 185 meters | Pins 2 & 3 closed |
|-----------+--------------------+---------------------------|
| | 300 meters | Pins 1 & 2 closed |
|------------------------------------------------------------|
| Note:Segment length is the total length of cable between |
| the two farthest cards on the segment. Each card on the |
| segment must have this option set the same. |
+------------------------------------------------------------+
IMG IMG 2
+------------------------------------------------------------+
| DIAGNOSTIC LED(S) |
|------------------------------------------------------------|
| LED | Color | Status | Condition |
|------+-------+--------+------------------------------------|
| LED1 | Green | On | Data is being transmitted or |
| | | | received |
|------+-------+--------+------------------------------------|
| LED1 | Green | Off | Data is not being transmitted or |
| | | | received |
|------+-------+--------+------------------------------------|
| LED2 | Red | On | Card is being accessed by host |
| | | | computer |
|------+-------+--------+------------------------------------|
| LED2 | Red | Off | Card is not being accessed by host |
| | | | computer |
+------------------------------------------------------------+