URI: 
  TEXT View Source
       
       # THOMAS-CONRAD CORPORATION
       
          TC6844 ARC CARD/SE30
       
          NIC Type              ArcNet                                   
          Chip Set              NCR 90C26                                
          Data Bus              Mac SE/30                                
          Network Transfer Rate 2.5Mbps                                  
          Topology              Linear Bus                               
          Wiring Type           RG-62A/U 93ohm coaxial                   
          Boot ROM              Not available                            
       
   IMG IMG 1
          
       
          +------------------------------------------------------------+
          |                        CONNECTIONS                         |
          |------------------------------------------------------------|
          |       Function       | Label |      Function       | Label |
          |----------------------+-------+---------------------+-------|
          | Header to connector  |  J1A  | RG-62A/U 93ohm      |  J2   |
          | card                 |       | coaxial connector   |       |
          |----------------------+-------+---------------------+-------|
          | Header to main board |  J1B  |                     |       |
          +------------------------------------------------------------+
       
          +------------------------------------------------------------+
          |                EXTENDED RANGE CONFIGURATION                |
          |------------------------------------------------------------|
          |    Response Time    |  Recon Time   |    JP1    |   JP2    |
          |---------------------+---------------+-----------+----------|
          |       74.7 uS       |    840 mS     |   Open    |   Open   |
          |---------------------+---------------+-----------+----------|
          |      283.4 uS       |    1.68 S     |  Closed   |   Open   |
          |---------------------+---------------+-----------+----------|
          |      561.8 uS       |    1.68 S     |   Open    |  Closed  |
          |---------------------+---------------+-----------+----------|
          |      1.1186 mS      |    1.68 S     |  Closed   |  Closed  |
          |------------------------------------------------------------|
          |      Note:This setting should only be changed when the     |
          |      length of the ArcNet segments exceed 6000 meters.     |
          +------------------------------------------------------------+
       
          +------------------------------------------------------------+
          |                        NODE ADDRESS                        |
          |------------------------------------------------------------|
          |Setting|SW1/1 |SW1/2 |SW1/3 |SW1/4 |SW1/5 |SW1/6|SW1/7|SW1/8|
          |-------+------+------+------+------+------+-----+-----+-----|
          |   1   | Off  |  On  |  On  |  On  |  On  | On  | On  | On  |
          |-------+------+------+------+------+------+-----+-----+-----|
          |   2   |  On  | Off  |  On  |  On  |  On  | On  | On  | On  |
          |-------+------+------+------+------+------+-----+-----+-----|
          |   3   | Off  | Off  |  On  |  On  |  On  | On  | On  | On  |
          |-------+------+------+------+------+------+-----+-----+-----|
          |   4   |  On  |  On  | Off  |  On  |  On  | On  | On  | On  |
          |-------+------+------+------+------+------+-----+-----+-----|
          |   5   | Off  |  On  | Off  |  On  |  On  | On  | On  | On  |
          |-------+------+------+------+------+------+-----+-----+-----|
          |  249  | Off  |  On  |  On  | Off  | Off  | Off | Off | Off |
          |-------+------+------+------+------+------+-----+-----+-----|
          |  250  |  On  | Off  |  On  | Off  | Off  | Off | Off | Off |
          |-------+------+------+------+------+------+-----+-----+-----|
          |  251  | Off  | Off  |  On  | Off  | Off  | Off | Off | Off |
          |-------+------+------+------+------+------+-----+-----+-----|
          |  252  |  On  |  On  | Off  | Off  | Off  | Off | Off | Off |
          |-------+------+------+------+------+------+-----+-----+-----|
          |  253  | Off  |  On  | Off  | Off  | Off  | Off | Off | Off |
          |------------------------------------------------------------|
          |     Note: A total of 253 node address settings are         |
          |     available. The switches are a binary representation of |
          |     the decimal node addresses. SW1/8 is the Most          |
          |     Significant Bit and switch SW1/1 is the Least          |
          |     Significant Bit. The switches have the following       |
          |     decimal values: SW1/8=128, SW1/7=64, SW1/6=32,         |
          |     SW1/5=16, SW1/4=8, SW1/3=4, SW1/2=2, SW1/1=1. Turn off |
          |     the switches and add the values of the switches that   |
          |     are off to obtain the correct node address. (Off=1,    |
          |     On=0)                                                  |
          |                                                            |
          |     Addresses 0, 254, and 255 are reserved and should not  |
          |     be used.                                               |
          +------------------------------------------------------------+