       # ADC KENTROX
       
          T-SMART MODELS 77111 AND 77961 (VER. 1)
       
          Card Type         T1 CSU                                       
          Chipset           Unidentified                                 
          T1 Transfer Rate  1.544Mbps                                    
          T1 Protocol       AMI, B8ZS                                    
          Frame Type        SF, ESF                                      
          Data Bus          Serial                                       
       
   IMG IMG 1
          
       
          +------------------------------------------------------------+
          |                        CONNECTIONS                         |
          |------------------------------------------------------------|
          |       Function        | Label |      Function      | Label |
          |-----------------------+-------+--------------------+-------|
          | Monitor receive       |  J1   | Monitor transmit   |  J8   |
          | equalization in jack  |       | monitor jack       |       |
          |-----------------------+-------+--------------------+-------|
          | Monitor receive       |  J2   | DC power in/alarm  |  P1   |
          | network out jack      |       | signal out (see    |       |
          |                       |       | pinout below       |       |
          |-----------------------+-------+--------------------+-------|
          | Serial control port   |  J3   | T1 line out        |  P2   |
          |                       |       | (network           |       |
          |                       |       | interface)         |       |
          |-----------------------+-------+--------------------+-------|
          | T1 line in (equipment |  J4   | Ground             |  P3   |
          | interface)            |       |                    |       |
          |-----------------------+-------+--------------------+-------|
          | Monitor receive       |  J5   | Local loopback     |  S1   |
          | monitor jack          |       | test switch        |       |
          |-----------------------+-------+--------------------+-------|
          | Monitor transmit      |  J6   | Alarm cut-off      |  S2   |
          | network in jack       |       | switch             |       |
          |-----------------------+-------+--------------------+-------|
          | Monitor transmit      |  J7   | Code generator     |  S3   |
          | equalization out jack |       | switch             |       |
          +------------------------------------------------------------+
       
          +------------------------------------------------------------+
          |                         P1 PINOUT                          |
          |------------------------------------------------------------|
          |    Function     | Screw |         Function         | Screw |
          |-----------------+-------+--------------------------+-------|
          | +20V to +56V DC |   1   | Chassis ground           |   4   |
          | power in        |       |                          |       |
          |-----------------+-------+--------------------------+-------|
          | Not used        |   2   | Alarm relay common       |   5   |
          |-----------------+-------+--------------------------+-------|
          | -20V to -56V DC |   3   | Alarm relay normally     |   6   |
          | power in        |       | open contact             |       |
          |------------------------------------------------------------|
          |      Note:Do not use both P1 screw 4 and P3.               |
          +------------------------------------------------------------+
       
          +------------------------------------------------------------+
          |                 USER CONFIGURABLE SETTINGS                 |
          |------------------------------------------------------------|
          |                Setting                 | Label | Position  |
          |----------------------------------------+-------+-----------|
          | » | Power drawn from SC1 terminals     |  JB1  |   LOCAL   |
          |---+------------------------------------+-------+-----------|
          |   | Power drawn from T1 line           |  JB1  |   LINE    |
          |---+------------------------------------+-------+-----------|
          | » | Simplex loop enabled               |  JP1  | Pins 1 &  |
          |   |                                    |       | 2 closed  |
          |---+------------------------------------+-------+-----------|
          |   | Simplex loop disabled              |  JP1  | Pins 2 &  |
          |   |                                    |       | 3 closed  |
          |---+------------------------------------+-------+-----------|
          | » | Alarm Indication Signal transmit   | S5/4  |    Off    |
          |   | delay set to 5 mS                  |       |           |
          |---+------------------------------------+-------+-----------|
          |   | Alarm Indication Signal transmit   | S5/4  |    On     |
          |   | delay set to 1 second              |       |           |
          |---+------------------------------------+-------+-----------|
          | » | Control port uses 8 data bits      | S5/7  |    Off    |
          |---+------------------------------------+-------+-----------|
          |   | Control port uses 7 data bits      | S5/7  |    On     |
          |---+------------------------------------+-------+-----------|
          | » | Control port uses 1 stop bit       | S5/8  |    Off    |
          |---+------------------------------------+-------+-----------|
          |   | Control port uses 2 stop bits      | S5/8  |    On     |
          |------------------------------------------------------------|
          |      Note:Jumper block JB1 has the words LINE and LOCAL    |
          |      printed on the side. The word indicated should face   |
          |      towards the user.                                     |
          +------------------------------------------------------------+
       
          +------------------------------------------------------------+
          |                  CODE GENERATOR OPERATION                  |
          |------------------------------------------------------------|
          |               Setting               |          S4          |
          |-------------------------------------+----------------------|
          |       Standard line loopback        |      Position 0      |
          |-------------------------------------+----------------------|
          |        Kentrox line loopback        |      Position 1      |
          |-------------------------------------+----------------------|
          |       Standard test loopback        |      Position 2      |
          |-------------------------------------+----------------------|
          |        Kentrox test loopback        |      Position 3      |
          |-------------------------------------+----------------------|
          |       Standard local loopback       |      Position 4      |
          |-------------------------------------+----------------------|
          |       Kentrox local loopback        |      Position 5      |
          |-------------------------------------+----------------------|
          |       Standard reset loopback       |      Position 6      |
          |-------------------------------------+----------------------|
          |       Kentrox reset loopback        |      Position 7      |
          |-------------------------------------+----------------------|
          |      Quasi-random test pattern      |      Position 8      |
          |-------------------------------------+----------------------|
          |         1 in 8 test pattern         |      Position 9      |
          |------------------------------------------------------------|
          |      Note:To generate the code indicated, switch S4 must   |
          |      be pushed for one-half second. To stop generating the |
          |      code, push S4 again.                                  |
          +------------------------------------------------------------+
       
          +------------------------------------------------------------+
          |                CONTROL PORT SPEED SELECTION                |
          |------------------------------------------------------------|
          |      Setting      |    S5/1     |    S5/2     |    S5/3    |
          |-------------------+-------------+-------------+------------|
          |   |   19.2Kbps    |     On      |     On      |     On     |
          |---+---------------+-------------+-------------+------------|
          | » |    9600bps    |     Off     |     On      |     On     |
          |---+---------------+-------------+-------------+------------|
          |   |    4800bps    |     On      |     Off     |     On     |
          |---+---------------+-------------+-------------+------------|
          |   |    2400bps    |     Off     |     Off     |     On     |
          |---+---------------+-------------+-------------+------------|
          |   |    1200bps    |     On      |     On      |    Off     |
          |---+---------------+-------------+-------------+------------|
          |   |    600bps     |     Off     |     On      |    Off     |
          |---+---------------+-------------+-------------+------------|
          |   |    300bps     |     On      |     Off     |    Off     |
          +------------------------------------------------------------+
       
          +------------------------------------------------------------+
          |                  LINE BUILD OUT SELECTION                  |
          |------------------------------------------------------------|
          |      Setting       |        S6         |        S7         |
          |--------------------+-------------------+-------------------|
          |        0 dB        |        Off        |        Off        |
          |--------------------+-------------------+-------------------|
          |      -7.5 dB       |        On         |        Off        |
          |--------------------+-------------------+-------------------|
          |       -15 dB       |        Off        |        On         |
          |--------------------+-------------------+-------------------|
          |      -22.5 dB      |        On         |        On         |
          +------------------------------------------------------------+
       
          +------------------------------------------------------------+
          |               CONTROL PORT PARITY SELECTION                |
          |------------------------------------------------------------|
          |        Setting         |      S5/5       |      S5/6       |
          |------------------------+-----------------+-----------------|
          | » |     No parity      |       On        |       N/A       |
          |---+--------------------+-----------------+-----------------|
          |   |     Odd parity     |       Off       |       On        |
          |---+--------------------+-----------------+-----------------|
          |   |    Even parity     |       Off       |       Off       |
          +------------------------------------------------------------+
       
          +------------------------------------------------------------+
          |                     DIAGNOSTIC LED(S)                      |
          |------------------------------------------------------------|
          |  LED   | Color  |  Status  |           Condition           |
          |--------+--------+----------+-------------------------------|
          |  LOC   | Yellow |    On    |    Local loopback test in     |
          |        |        |          |           progress            |
          |--------+--------+----------+-------------------------------|
          |  LOC   | Yellow |   Off    |  Local loopback test not in   |
          |        |        |          |           progress            |
          |--------+--------+----------+-------------------------------|
          |  ACO   | Green  |    On    | Alarm condition exists and S2 |
          |        |        |          |       has been pressed        |
          |--------+--------+----------+-------------------------------|
          |  ACO   | Green  |   Off    | S2 has not been pressed or no |
          |        |        |          |    alarm condition exists     |
          |--------+--------+----------+-------------------------------|
          |  SEND  | Yellow |    On    |  Test or loopback code being  |
          |        |        |          | sent on indicated connection  |
          |--------+--------+----------+-------------------------------|
          |  SEND  | Yellow |   Off    |   Test or loopback code not   |
          |        |        |          |    being sent on indicated    |
          |        |        |          |          connection           |
          |--------+--------+----------+-------------------------------|
          |   TI   |  Red   |    On    |   Indicated alarm is on T1    |
          |        |        |          |           equipment           |
          |--------+--------+----------+-------------------------------|
          |   TI   |  Red   |   Off    | Indicated condition is not on |
          |        |        |          |         T1 equipment          |
          |--------+--------+----------+-------------------------------|
          |   NI   |  Red   |    On    |   Indicated alarm is on T1    |
          |        |        |          |       network interface       |
          |--------+--------+----------+-------------------------------|
          |   NI   |  Red   |   Off    | Indicated condition is not on |
          |        |        |          |     T1 network interface      |
          |--------+--------+----------+-------------------------------|
          |  DATA  | Green  |    On    | Valid data being received on  |
          |        |        |          |     indicated connection      |
          |--------+--------+----------+-------------------------------|
          |  DATA  | Green  |   Off    | No valid data being received  |
          |        |        |          |    on indicated connection    |
          |--------+--------+----------+-------------------------------|
          |  CODE  | Yellow |    On    |  Test or loopback code being  |
          |        |        |          |     received on indicated     |
          |        |        |          |          connection           |
          |--------+--------+----------+-------------------------------|
          |  CODE  | Yellow |   Off    |   Test or loopback code not   |
          |        |        |          |  being received on indicated  |
          |        |        |          |          connection           |
          |--------+--------+----------+-------------------------------|
          |  NET   | Yellow |    On    |   Network loopback test in    |
          |        |        |          |           progress            |
          |--------+--------+----------+-------------------------------|
          |  NET   | Yellow |   Off    | Network loopback test not in  |
          |        |        |          |           progress            |
          |--------+--------+----------+-------------------------------|
          | TA/FEL | Yellow |    On    | Remote CSU/DSU loopback test  |
          |        |        |          |  in progress or Set or Test   |
          |        |        |          |       code transmitted        |
          |--------+--------+----------+-------------------------------|
          | TA/FEL | Yellow | Blinking | Remote CSU/DSU loopback test  |
          |        |        |          |           verified            |
          |--------+--------+----------+-------------------------------|
          | TA/FEL | Yellow |   Off    | Remote CSU/DSU loopback test  |
          |        |        |          |  not in progress and Set or   |
          |        |        |          |   Test code not transmitted   |
          |--------+--------+----------+-------------------------------|
          |  PWR   | Green  |    On    |          Power is on          |
          |--------+--------+----------+-------------------------------|
          |  PWR   |  Red   |    On    |       Self-test failed        |
          |--------+--------+----------+-------------------------------|
          |  PWR   |  N/A   |   Off    |         Power is off          |
          |--------+--------+----------+-------------------------------|
          |  EER   |  Red   |    On    |    Error rate on indicated    |
          |        |        |          | connection exceeds threshold  |
          |--------+--------+----------+-------------------------------|
          |  EER   |  Red   |   Off    |    Error rate on indicated    |
          |        |        |          |  connection does not exceed   |
          |        |        |          |           threshold           |
          |--------+--------+----------+-------------------------------|
          |  OOF   |  Red   |    On    |    Signal is out of frame     |
          |        |        |          | synchronization on indicated  |
          |        |        |          |          connection           |
          |--------+--------+----------+-------------------------------|
          |  OOF   |  Red   |   Off    |  Signal is not out of frame   |
          |        |        |          | synchronization on indicated  |
          |        |        |          |          connection           |
          +------------------------------------------------------------+
       
          +------------------------------------------------------------+
          |                 DIAGNOSTIC LED(S) (CON'T)                  |
          |------------------------------------------------------------|
          | LED | Color  |  Status  |            Condition             |
          |-----+--------+----------+----------------------------------|
          | YEL | Yellow |    On    | Yellow Alarm condition detected  |
          |     |        |          |     on indicated connection      |
          |-----+--------+----------+----------------------------------|
          | YEL | Yellow |   Off    |    Yellow Alarm condition not    |
          |     |        |          | detected on indicated connection |
          |-----+--------+----------+----------------------------------|
          | PD  |  Red   |    On    |    Fewer than 1 high bit in 8    |
          |     |        |          | detected on indicated connection |
          |-----+--------+----------+----------------------------------|
          | PD  |  Red   |   Off    |    More than 1 high bit in 8     |
          |     |        |          | detected on indicated connection |
          |-----+--------+----------+----------------------------------|
          | KA  |  Red   |    On    | Keep-alive signal transmitted to |
          |     |        |          |       T1 network interface       |
          |-----+--------+----------+----------------------------------|
          | KA  |  Red   |   Off    |      Keep-alive signal not       |
          |     |        |          |    transmitted to T1 network     |
          |     |        |          |            interface             |
          |-----+--------+----------+----------------------------------|
          | LOS |  Red   |    On    |     Loss Of Signal condition     |
          |     |        |          | detected on indicated connection |
          |-----+--------+----------+----------------------------------|
          | LOS |  Red   |   Off    |   Loss Of Signal condition not   |
          |     |        |          | detected on indicated connection |
          |-----+--------+----------+----------------------------------|
          | AIS |  Red   |    On    |     Alarm Indication Signal      |
          |     |        |          |    condition detected for one    |
          |     |        |          |  second on indicated connection  |
          |-----+--------+----------+----------------------------------|
          | AIS |  Red   |   Off    |     Alarm Indication Signal      |
          |     |        |          |    condition not detected on     |
          |     |        |          |       indicated connection       |
          |-----+--------+----------+----------------------------------|
          | BPV |  Red   | Blinking |  Bipolar Variation detected on   |
          |     |        |          |  indicated connection (does not  |
          |     |        |          |        count B8ZS coding)        |
          |-----+--------+----------+----------------------------------|
          | BPV |  Red   |   Off    |  Bipolar Variation not detected  |
          |     |        |          |     on indicated connection      |
          +------------------------------------------------------------+