URI: 
  TEXT View Source
       
       # PARADYNE CORPORATION
       
          ACCULINK 3350 E1
       
          Card Type         Network Termination Unit                     
          NIC Type          E1                                           
          Chip Set          Unidentified                                 
          I/O Options       BNC connectors (2), auxiliary port (RJ-48),  
                            communication port (RJ-48), HDSL network     
                            interface via RJ-48 connector, test jacks    
                            (6), power jack                              
                                                                         
                            15-pin G.703 DTE port                        
          Maximum Data Rate 2.048Mbps                                    
          Data Bus          External                                     
       
   IMG IMG 1
          
       
          +------------------------------------------------------------+
          |                        CONNECTIONS                         |
          |------------------------------------------------------------|
          |    Function     | Label |         Function         | Label |
          |-----------------+-------+--------------------------+-------|
          | Test jack - Lp1 |  CN1  | Auxiliary port           |  CN8  |
          | HDSL line       |       |                          |       |
          |-----------------+-------+--------------------------+-------|
          | Test jack - Lp2 |  CN2  | Communication port       |  CN9  |
          | HDSL line       |       |                          |       |
          |-----------------+-------+--------------------------+-------|
          | Test jack - E1  |  CN3  | 15-pin DTE port          | CN10  |
          | line in         |       |                          |       |
          |-----------------+-------+--------------------------+-------|
          | Test jack - E1  |  CN4  | HDSL network interface   | CN11  |
          | line out        |       | via RJ-48 connector      |       |
          |-----------------+-------+--------------------------+-------|
          | Test jack - E1  |  CN5  | BNC connector - receive  |  RX   |
          | monitor In      |       |                          |       |
          |-----------------+-------+--------------------------+-------|
          | Test jack - E1  |  CN6  | BNC connector - transmit |  TX   |
          | monitor out     |       |                          |       |
          |-----------------+-------+--------------------------+-------|
          | Power Jack      |  CN7  |                          |       |
          +------------------------------------------------------------+
       
          +------------------------------------------------------------+
          |                 USER CONFIGURABLE SETTINGS                 |
          |------------------------------------------------------------|
          |                 Setting                 | Label | Position |
          |-----------------------------------------+-------+----------|
          | Open shield connection established      |  SW1  |    On    |
          |-----------------------------------------+-------+----------|
          | Earth shield connection established     |  SW1  |   Off    |
          |-----------------------------------------+-------+----------|
          | 120ohm balanced network interface       |  SW2  |    In    |
          | selected                                |       |          |
          |-----------------------------------------+-------+----------|
          | 75ohm unbalanced network interface      |  SW2  |   Out    |
          | selected                                |       |          |
          |------------------------------------------------------------|
          | Note: SW1 must be on when using the 120ohm interface       |
          +------------------------------------------------------------+
       
          +------------------------------------------------------------+
          |                     DIAGNOSTIC LED(S)                      |
          |------------------------------------------------------------|
          | LED  |  Color   |  Status  |           Condition           |
          |------+----------+----------+-------------------------------|
          |  OK  |  Green   |    On    |        NTU power is on        |
          |------+----------+----------+-------------------------------|
          |  OK  |   Green  | Blinking |  NTU is downloading software  |
          |------+----------+----------+-------------------------------|
          |  OK  |   Green  |   Off    | NTU power is off or detecting |
          |      |          |          |       a system failure        |
          |------+----------+----------+-------------------------------|
          | FAIL |  Yellow  |    On    |     Device error has been     |
          |      |          |          |           detected            |
          |------+----------+----------+-------------------------------|
          | FAIL |   Yellow |   Off    |   Device error has not been   |
          |      |          |          |           detected            |
          |------+----------+----------+-------------------------------|
          | FAIL |  Yellow  | Blinking | NTU is conducting a self test |
          |------+----------+----------+-------------------------------|
          | TST  |  Yellow  |    On    |  NTU is executing a loopback  |
          |      |          |          |        or pattern test        |
          |------+----------+----------+-------------------------------|
          | TST  |   Yellow |   Off    |  NTU is not executing a test  |
          |------+----------+----------+-------------------------------|
          | SIG1 |  Green   |    On    |      NTU is receiving a       |
          |      |          |          |    recoverable signal from    |
          |      |          |          |       network on loop 1       |
          |------+----------+----------+-------------------------------|
          | SIG1 |  Green   |   Off    | NTU cannot recover the signal |
          |      |          |          |    from network on loop 1     |
          |------+----------+----------+-------------------------------|
          | SIG2 |  Green   |    On    |      NTU is receiving a       |
          |      |          |          |    recoverable signal from    |
          |      |          |          |       network on loop 2       |
          |------+----------+----------+-------------------------------|
          | SIG2 |  Green   |   Off    | NTU cannot recover the signal |
          |      |          |          |    from network on loop 2     |
          |------+----------+----------+-------------------------------|
          | OOF  |  Yellow  |    On    |    Out of frame condition     |
          |      |          |          |      detected on network      |
          |------+----------+----------+-------------------------------|
          | OOF  |   Yellow |   Off    |  Out of frame condition not   |
          |      |          |          |      detected on network      |
          |------+----------+----------+-------------------------------|
          | ALM  |  Yellow  |    On    |  Alarm condition detected on  |
          |      |          |          |            network            |
          |------+----------+----------+-------------------------------|
          | ALM  |   Yellow |   Off    | Alarm condition not detected  |
          |      |          |          |          on network           |
          |------+----------+----------+-------------------------------|
          | SIG  |  Green   |    On    | A recoverable signal is being |
          |      |          |          | received from G.703 DTE port  |
          |------+----------+----------+-------------------------------|
          | SIG  |   Green  |   Off    | NTU cannot recover the signal |
          |      |          |          |      from G.703 DTE port      |
          |------+----------+----------+-------------------------------|
          | OFG  |  Yellow  |    On    |    Out of frame condition     |
          |      |          |          | detected on G.703 DTE signal  |
          |------+----------+----------+-------------------------------|
          | OFG  |   Yellow |   Off    |  Out of frame condition not   |
          |      |          |          | detected on G.703 DTE signal  |
          |------+----------+----------+-------------------------------|
          | ALMG |  Yellow  |    On    |  Alarm condition detected on  |
          |      |          |          |       G.703 DTE signal        |
          |------+----------+----------+-------------------------------|
          | ALMG |   Yellow |   Off    | Alarm condition not detected  |
          |      |          |          |      on G.703 DTE signal      |
          |------+----------+----------+-------------------------------|
          | PDV  |  Yellow  |    On    | A pulse density violation was |
          |      |          |          |  detected (and corrected) on  |
          |      |          |          |       G.703 DTE signal        |
          |------+----------+----------+-------------------------------|
          | PDV  |   Yellow |   Off    | A pulse density violation was |
          |      |          |          |   not detected on G.703 DTE   |
          |      |          |          |            signal             |
          |------+----------+----------+-------------------------------|
          | BPV  |  Yellow  |    On    |    A bipolar violation was    |
          |      |          |          |  detected (and corrected) on  |
          |      |          |          |       G.703 DTE signal        |
          |------+----------+----------+-------------------------------|
          | BPV  |   Yellow |   Off    |  A bipolar violation was not  |
          |      |          |          | detected on G.703 DTE signal  |
          +------------------------------------------------------------+