URI: 
  TEXT View Source
       
       # U.S. ROBOTICS, INC.
       
          SPORTSTER PCMCIA 14.4
       
          Modem Type             Data (synchronous/asynchronous)/Fax     
          Maximum Data Rate      14.4Kbps                                
          Maximum Fax Rate       14.4Kbps                                
          Data Bus               External                                
          Fax Class              Class I & II                            
          Data Modulation        Bell 103A/212A                          
          Protocol                                                       
                                 ITU-T V.21, V.22, V.22bis, V.23, V.32,  
                                 V.32bis                                 
          Fax Modulation         ITU-T V.17, V.21CH2, V.27ter, V.29      
          Protocol               
          Error                  MNP5, V.42, V.42bis                     
          Correction/Compression 
       
                            Proprietary AT Command Set
       
                                                                   V1253
       
          +------------------------------------------------------------+
          |                  BIT-MAPPED REGISTER S13                   |
          |------------------------------------------------------------|
          | Format          | AT [cmds] S13=n [cmds]                   |
          |-----------------+------------------------------------------|
          | Example:        | ATS13=139<CR>                            |
          |-----------------+------------------------------------------|
          | Default:        | 0                                        |
          |-----------------+------------------------------------------|
          | Range:          | 0 - 89                                   |
          |-----------------+------------------------------------------|
          | Unit:           | Bit-mapped                               |
          |-----------------+------------------------------------------|
          | Description:    | Controls DTR reset, DTR dialing, reset   |
          |                 | dialing, and MNP3.                       |
          |------------------------------------------------------------|
          |   Bit    | Value         |            Function             |
          |----------+---------------+---------------------------------|
          |    0     | » 0 1         | DTR normal.                     |
          |          |               |                                 |
          |          |               | Reset on low DTR.               |
          |----------+---------------+---------------------------------|
          |    1     | » 0           | Not used.                       |
          |----------+---------------+---------------------------------|
          |    2     | » 0           | Not used.                       |
          |----------+---------------+---------------------------------|
          |    3     | » 0 1         | DTR dialing disabled.           |
          |          |               |                                 |
          |          |               | DTR dialing enabled.            |
          |----------+---------------+---------------------------------|
          |    4     | » 0 1         | Reset dialing disabled.         |
          |          |               |                                 |
          |          |               | Reset dialing enabled.          |
          |----------+---------------+---------------------------------|
          |    5     | » 0           | Not used.                       |
          |----------+---------------+---------------------------------|
          |    6     | » 0 1         | MNP 3 enabled.                  |
          |          |               |                                 |
          |          |               | MNP 3 disabled.                 |
          |----------+---------------+---------------------------------|
          |    7     | » 0           | Not used.                       |
          +------------------------------------------------------------+
       
          +------------------------------------------------------------+
          |                  BIT-MAPPED REGISTER S15                   |
          |------------------------------------------------------------|
          | Format        | AT [cmds] S15=n [cmds]                     |
          |---------------+--------------------------------------------|
          | Example:      | ATS15=139<CR>                              |
          |---------------+--------------------------------------------|
          | Default:      | 0                                          |
          |---------------+--------------------------------------------|
          | Range:        | 0 - 56                                     |
          |---------------+--------------------------------------------|
          | Unit:         | Bit-mapped                                 |
          |---------------+--------------------------------------------|
          | Description:  | Controls non-error-correcting mode buffer, |
          |               | MNP4, and BS/DEL switch.                   |
          |------------------------------------------------------------|
          |   Bit   | Value |                 Function                 |
          |---------+-------+------------------------------------------|
          |    0    | » 0   | Not used.                                |
          |---------+-------+------------------------------------------|
          |    1    | » 0   | Not used.                                |
          |---------+-------+------------------------------------------|
          |    2    | » 0   | Not used.                                |
          |---------+-------+------------------------------------------|
          |    3    | » 0 1 | Non-error-correcting mode transmit       |
          |         |       | buffer set to 1.5KB.                     |
          |         |       |                                          |
          |         |       | Non-error-correcting mode transmit       |
          |         |       | buffer set to 128 bytes.                 |
          |---------+-------+------------------------------------------|
          |    4    | » 0 1 | MNP 4 enabled.                           |
          |         |       |                                          |
          |         |       | MNP 4 disabled.                          |
          |---------+-------+------------------------------------------|
          |    5    | » 0 1 | Use backspace key for delete disabled.   |
          |         |       |                                          |
          |         |       | Use backspace key for delete enabled.    |
          +------------------------------------------------------------+
       
          +------------------------------------------------------------+
          |                  BIT-MAPPED REGISTER S27                   |
          |------------------------------------------------------------|
          | Format          | AT [cmds] S27=n [cmds]                   |
          |-----------------+------------------------------------------|
          | Example:        | ATS27=139<CR>                            |
          |-----------------+------------------------------------------|
          | Default:        | 0                                        |
          |-----------------+------------------------------------------|
          | Range:          | 0 - 191                                  |
          |-----------------+------------------------------------------|
          | Unit:           | Bit-mapped                               |
          |-----------------+------------------------------------------|
          | Description:    | Controls V.21, V.32 encoding and         |
          |                 | modulation, V.42 answer tone and         |
          |                 | handshake, and 9600 result codes.        |
          |------------------------------------------------------------|
          |    Bit    | Value  |               Function                |
          |-----------+--------+---------------------------------------|
          |     0     | » 0 1  | V.21 disabled.                        |
          |           |        |                                       |
          |           |        | V.21 enabled.                         |
          |-----------+--------+---------------------------------------|
          |     1     | » 0 1  | V.32 trellis coding disabled.         |
          |           |        |                                       |
          |           |        | V.32 trellis coding enabled.          |
          |-----------+--------+---------------------------------------|
          |     2     | » 0 1  | V.32 modulation enabled.              |
          |           |        |                                       |
          |           |        | V.32 modulation disabled.             |
          |-----------+--------+---------------------------------------|
          |     3     | » 0 1  | 2100Hz answer tone enabled.           |
          |           |        |                                       |
          |           |        | 2100Hz answer tone disabled.          |
          |-----------+--------+---------------------------------------|
          |   5, 4    | » 00   | V.42 detect, LAPM and MNP enabled.    |
          |           | 01 10  |                                       |
          |           | 11     | V.42 detect and LAPM enabled.         |
          |           |        |                                       |
          |           |        | MNP enabled.                          |
          |           |        |                                       |
          |           |        | LAPM enabled.                         |
          |-----------+--------+---------------------------------------|
          |     6     | » 0    | Not used.                             |
          |-----------+--------+---------------------------------------|
          |     7     | » 0 1  | Actual result codes displayed.        |
          |           |        |                                       |
          |           |        | Force 9600 result codes.              |
          +------------------------------------------------------------+
       
          +------------------------------------------------------------+
          |              COMPRESSION AND ERROR CORRECTION              |
          |------------------------------------------------------------|
          | Format          | AT [cmds] S51=n [cmds]                   |
          |-----------------+------------------------------------------|
          | Example:        | ATS51=139<CR>                            |
          |-----------------+------------------------------------------|
          | Default:        | 0                                        |
          |-----------------+------------------------------------------|
          | Range:          | 0 - 7                                    |
          |-----------------+------------------------------------------|
          | Unit:           | Bit-mapped                               |
          |-----------------+------------------------------------------|
          | Description:    | Selects compression and error correction |
          |                 | for specific modulations.                |
          |------------------------------------------------------------|
          |   Bit    | Value     |              Function               |
          |----------+-----------+-------------------------------------|
          |    0     | » 0 1     | MNP/V.42 disabled during V.22       |
          |          |           | operation.                          |
          |          |           |                                     |
          |          |           | MNP/V.42 disabled during V.22       |
          |          |           | operation.                          |
          |----------+-----------+-------------------------------------|
          |    1     | » 0 1     | MNP/V.42 disabled during V.22bis    |
          |          |           | operation.                          |
          |          |           |                                     |
          |          |           | MNP/V.42 disabled during V.22bis    |
          |          |           | operation.                          |
          |----------+-----------+-------------------------------------|
          |    2     | » 0 1     | MNP/V.42 disabled during V.32bis    |
          |          |           | operation.                          |
          |          |           |                                     |
          |          |           | MNP/V.42 disabled during V.32bis    |
          |          |           | operation.                          |
          +------------------------------------------------------------+
       
          +------------------------------------------------------------+
          |                        BREAK LENGTH                        |
          |------------------------------------------------------------|
          | Type:        | Register                                    |
          |--------------+---------------------------------------------|
          | Format:      | AT [cmds] S21=n [cmds]                      |
          |--------------+---------------------------------------------|
          | Example:     | ATS21=20<CR>                                |
          |--------------+---------------------------------------------|
          | Default:     | 10                                          |
          |--------------+---------------------------------------------|
          | Range:       | Unidentified                                |
          |--------------+---------------------------------------------|
          | Unit:        | 10 milliseconds                             |
          |--------------+---------------------------------------------|
          | Description: | Sets the length of error control mode       |
          |              | breaks sent from DCE to DTE.                |
          +------------------------------------------------------------+
       
          +------------------------------------------------------------+
          |                         BREAK TYPE                         |
          |------------------------------------------------------------|
          | Type:        | Configuration                               |
          |--------------+---------------------------------------------|
          | Format:      | AT [cmds] &Yn [cmds]                        |
          |--------------+---------------------------------------------|
          | Example:     | AT &Y0<CR>                                  |
          |--------------+---------------------------------------------|
          | Description: | Configures action of break signal.          |
          |--------------+---------------------------------------------|
          | Command      |                  Function                   |
          |--------------+---------------------------------------------|
          | &Y0          | Break empties buffer.                       |
          |--------------+---------------------------------------------|
          | » &Y1        | Break empties buffer and is sent            |
          |              | immediately.                                |
          |--------------+---------------------------------------------|
          | &Y2          | Break does not empty buffer and is sent     |
          |              | immediately.                                |
          |--------------+---------------------------------------------|
          | &Y3          | Break does not empty buffer and is sent     |
          |              | with transmitted data.                      |
          +------------------------------------------------------------+
       
          +------------------------------------------------------------+
          |                   CONNECTION SPEED FORCE                   |
          |------------------------------------------------------------|
          | Type:        | Configuration                               |
          |--------------+---------------------------------------------|
          | Format:      | AT [cmds] &Nn [cmds]                        |
          |--------------+---------------------------------------------|
          | Example:     | AT &N1 DT555-1212<CR>                       |
          |--------------+---------------------------------------------|
          | Description: | Sets required connection speed.,            |
          |--------------+---------------------------------------------|
          | Command      |                  Function                   |
          |--------------+---------------------------------------------|
          | » &N0        | Variable.                                   |
          |--------------+---------------------------------------------|
          | &N1          | 300bps                                      |
          |--------------+---------------------------------------------|
          | &N2          | 1200bps                                     |
          |--------------+---------------------------------------------|
          | &N3          | 2400bps                                     |
          |--------------+---------------------------------------------|
          | &N4          | 4800bps                                     |
          |--------------+---------------------------------------------|
          | &N5          | 7200bps                                     |
          |--------------+---------------------------------------------|
          | &N6          | 9600bps                                     |
          |--------------+---------------------------------------------|
          | &N7          | 12Kbps                                      |
          |--------------+---------------------------------------------|
          | &N8          | 14.4Kbps                                    |
          +------------------------------------------------------------+
       
          +------------------------------------------------------------+
          |                   ERROR CORRECTION MODE                    |
          |------------------------------------------------------------|
          | Type:        | Configuration                               |
          |--------------+---------------------------------------------|
          | Format:      | AT [cmds] &Mn [cmds]                        |
          |--------------+---------------------------------------------|
          | Example:     | AT &M1 %C1<CR>                              |
          |--------------+---------------------------------------------|
          | Description: | Selects active error correction protocols.  |
          |--------------+---------------------------------------------|
          | Command      |                  Function                   |
          |--------------+---------------------------------------------|
          | &M0          | Normal mode only.                           |
          |--------------+---------------------------------------------|
          | » &M4        | Auto-detect mode.                           |
          |--------------+---------------------------------------------|
          | &M5          | ARQ mode only.                              |
          +------------------------------------------------------------+
       
          +------------------------------------------------------------+
          |                 ESCAPE CHARACTER RESPONSE                  |
          |------------------------------------------------------------|
          | Type:        | Register                                    |
          |--------------+---------------------------------------------|
          | Format:      | AT [cmds] S14=n [cmds]                      |
          |--------------+---------------------------------------------|
          | Example:     | ATS14=20<CR>                                |
          |--------------+---------------------------------------------|
          | Default:     | 0                                           |
          |--------------+---------------------------------------------|
          | Description: | Controls reaction to escape character.      |
          |--------------+---------------------------------------------|
          | Command      |                  Function                   |
          |--------------+---------------------------------------------|
          | » S14=0      | Normal operation.                           |
          |--------------+---------------------------------------------|
          | S14=1        | When +++ is received, modem goes on hook,   |
          |              | enters command state and sends NO CARRIER   |
          |              | result code.                                |
          +------------------------------------------------------------+
       
          +------------------------------------------------------------+
          |                   EXTENDED RESULT CODES                    |
          |------------------------------------------------------------|
          | Type:        | Configuration                               |
          |--------------+---------------------------------------------|
          | Format:      | AT [cmds] &An [cmds]                        |
          |--------------+---------------------------------------------|
          | Example:     | AT &A1 %C1<CR>                              |
          |--------------+---------------------------------------------|
          | Description: | Selects extended result codes.              |
          |--------------+---------------------------------------------|
          | Command      |                  Function                   |
          |--------------+---------------------------------------------|
          | &A0          | Extended result codes disabled.             |
          |--------------+---------------------------------------------|
          | &A1          | ARQ result codes enabled.                   |
          |--------------+---------------------------------------------|
          | &A2          | V.32 result code enabled.                   |
          |--------------+---------------------------------------------|
          | » &A3        | Error control and compression result codes  |
          |              | enabled.                                    |
          +------------------------------------------------------------+
       
          +------------------------------------------------------------+
          |                FLOW CONTROL CHARACTER - XON                |
          |------------------------------------------------------------|
          | Type:        | Register                                    |
          |--------------+---------------------------------------------|
          | Format:      | AT [cmds] S22=n [cmds]                      |
          |--------------+---------------------------------------------|
          | Example:     | ATS22=20<CR>                                |
          |--------------+---------------------------------------------|
          | Default:     | 17                                          |
          |--------------+---------------------------------------------|
          | Range:       | 0-127                                       |
          |--------------+---------------------------------------------|
          | Unit:        | ASCII                                       |
          |--------------+---------------------------------------------|
          | Description: | Sets the character used to represent XON.   |
          +------------------------------------------------------------+
       
          +------------------------------------------------------------+
          |               FLOW CONTROL CHARACTER - XOFF                |
          |------------------------------------------------------------|
          | Type:        | Register                                    |
          |--------------+---------------------------------------------|
          | Format:      | AT [cmds] S23=n [cmds]                      |
          |--------------+---------------------------------------------|
          | Example:     | ATS23=20<CR>                                |
          |--------------+---------------------------------------------|
          | Default:     | 19                                          |
          |--------------+---------------------------------------------|
          | Range:       | 0-127                                       |
          |--------------+---------------------------------------------|
          | Unit:        | ASCII                                       |
          |--------------+---------------------------------------------|
          | Description: | Sets the character used to represent XOFF.  |
          +------------------------------------------------------------+
       
          +------------------------------------------------------------+
          |                  FLOW CONTROL PASSTHROUGH                  |
          |------------------------------------------------------------|
          | Type:        | Configuration                               |
          |--------------+---------------------------------------------|
          | Format:      | AT [cmds] &In [cmds]                        |
          |--------------+---------------------------------------------|
          | Example:     | AT &I0 &W<CR>                               |
          |--------------+---------------------------------------------|
          | Description: | Allows modem to act on, then transmit       |
          |              | XON/XOFF characters.                        |
          |--------------+---------------------------------------------|
          | Command      |                  Function                   |
          |--------------+---------------------------------------------|
          | » &I0        | Software flow control disabled.             |
          |--------------+---------------------------------------------|
          | &I1          | XON/XOFF passthrough enabled.               |
          |--------------+---------------------------------------------|
          | &I2          | XON/XOFF passthrough disabled.              |
          |--------------+---------------------------------------------|
          | &I3          | ENQ/ACK enabled in host mode.               |
          |--------------+---------------------------------------------|
          | &I4          | ENQ/ACK enabled in terminal mode.           |
          |--------------+---------------------------------------------|
          | &I5          | XON/XOFF passthrough disabled in error      |
          |              | correction mode.                            |
          +------------------------------------------------------------+
       
          +------------------------------------------------------------+
          |                     FLOW CONTROL TYPE                      |
          |------------------------------------------------------------|
          | Type:        | Configuration                               |
          |--------------+---------------------------------------------|
          | Format:      | AT [cmds] &Hn [cmds]                        |
          |--------------+---------------------------------------------|
          | Example:     | AT &H0 A<CR>                                |
          |--------------+---------------------------------------------|
          | Description: | Sets type of flow control used by modem.    |
          |--------------+---------------------------------------------|
          | Command      |                  Function                   |
          |--------------+---------------------------------------------|
          | &H0          | Flow control disabled.                      |
          |--------------+---------------------------------------------|
          | » &H1        | CTS/RTS flow control enabled.               |
          |--------------+---------------------------------------------|
          | &H2          | XON/XOFF flow control enabled.              |
          |--------------+---------------------------------------------|
          | &H3          | CTS/RTS and XON/XOFF flow control enabled.  |
          +------------------------------------------------------------+
       
          +------------------------------------------------------------+
          |                        HELP SCREENS                        |
          |------------------------------------------------------------|
          | Type:        | Immediate                                   |
          |--------------+---------------------------------------------|
          | Format:      | AT <prefix>$                                |
          |--------------+---------------------------------------------|
          | Example:     | AT &$<CR>                                   |
          |--------------+---------------------------------------------|
          | Description: | Shows command help screens for all commands |
          |              | beginning with the given prefix, or no      |
          |              | prefix if none is given.                    |
          |--------------+---------------------------------------------|
          |   Command    |                  Function                   |
          |--------------+---------------------------------------------|
          |      $       | Shows ATx help screen.                      |
          |--------------+---------------------------------------------|
          |      &$      | Shows AT&x help screen.                     |
          +------------------------------------------------------------+
       
          +------------------------------------------------------------+
          |                      INACTIVITY TIMER                      |
          |------------------------------------------------------------|
          | Type:        | Register                                    |
          |--------------+---------------------------------------------|
          | Format:      | AT [cmds] S19=n [cmds]                      |
          |--------------+---------------------------------------------|
          | Example:     | ATS19=20<CR>                                |
          |--------------+---------------------------------------------|
          | Default:     | 0                                           |
          |--------------+---------------------------------------------|
          | Range:       | Unidentified                                |
          |--------------+---------------------------------------------|
          | Unit:        | 1 minute                                    |
          |--------------+---------------------------------------------|
          | Description: | Sets the length of time that the modem does |
          |              | not receive information before it           |
          |              | disconnects.                                |
          +------------------------------------------------------------+
       
          +------------------------------------------------------------+
          |                      LOCK SERIAL PORT                      |
          |------------------------------------------------------------|
          | Type:        | Configuration                               |
          |--------------+---------------------------------------------|
          | Format:      | AT [cmds] &Bn [cmds]                        |
          |--------------+---------------------------------------------|
          | Example:     | AT &N9 &B0<CR>                              |
          |--------------+---------------------------------------------|
          | Description: | Sets operation of serial port speed.        |
          |--------------+---------------------------------------------|
          | Command      |                  Function                   |
          |--------------+---------------------------------------------|
          | &B0          | Serial speed follows connect speed          |
          |--------------+---------------------------------------------|
          | » &B1        | Serial speed locked.                        |
          |--------------+---------------------------------------------|
          | &B2          | Serial speed locked in ARQ mode only,       |
          +------------------------------------------------------------+
       
          +------------------------------------------------------------+
          |                     REPORT INFORMATION                     |
          |------------------------------------------------------------|
          | Type:        | Immediate                                   |
          |--------------+---------------------------------------------|
          | Format:      | AT [cmds] In [cmds]                         |
          |--------------+---------------------------------------------|
          | Example:     | AT I1 O<CR>                                 |
          |--------------+---------------------------------------------|
          | Description: | Displays modem properties.                  |
          |--------------+---------------------------------------------|
          |   Command    |                  Function                   |
          |--------------+---------------------------------------------|
          |      I0      | Reports product code.                       |
          |--------------+---------------------------------------------|
          |      I1      | Reports ROM checksum result.                |
          |--------------+---------------------------------------------|
          |      I2      | Reports RAM checksum result.                |
          |--------------+---------------------------------------------|
          |      I3      | Reports firmware version.                   |
          |--------------+---------------------------------------------|
          |      I4      | Reports current command settings.           |
          |--------------+---------------------------------------------|
          |      I5      | Reports current NVRAM settings.             |
          |--------------+---------------------------------------------|
          |      I6      | Reports current connection’s statistics.    |
          |--------------+---------------------------------------------|
          |      I7      | Reports configuration.                      |
          +------------------------------------------------------------+
       
          +------------------------------------------------------------+
          |                     TONE DIALING TEST                      |
          |------------------------------------------------------------|
          | Type:        | Register                                    |
          |--------------+---------------------------------------------|
          | Format:      | AT [cmds] S16=n [cmds]                      |
          |--------------+---------------------------------------------|
          | Example:     | ATS16=139<CR>                               |
          |--------------+---------------------------------------------|
          | Description: | Selects the tone dialing test               |
          |--------------+---------------------------------------------|
          | Command      |                  Function                   |
          |--------------+---------------------------------------------|
          | » S16=0      | Tone dialing test disabled.                 |
          |--------------+---------------------------------------------|
          | S16=2        | Tone dialing test enabled.                  |
          +------------------------------------------------------------+
       
          +------------------------------------------------------------+
          |                V.32 AND V.32bis MODULATIONS                |
          |------------------------------------------------------------|
          | Format        | AT [cmds] S34=n [cmds]                     |
          |---------------+--------------------------------------------|
          | Example:      | ATS34=139<CR>                              |
          |---------------+--------------------------------------------|
          | Default:      | 0                                          |
          |---------------+--------------------------------------------|
          | Range:        | 0 - 9                                      |
          |---------------+--------------------------------------------|
          | Unit:         | Bit-mapped                                 |
          |---------------+--------------------------------------------|
          | Description:  | Controls V.32 and V.32bis modulations.     |
          |------------------------------------------------------------|
          |   Bit   |    Value    |              Function              |
          |---------+-------------+------------------------------------|
          |    0    | » 0 1       | V.32bis enabled.                   |
          |         |             |                                    |
          |         |             | V.32bis disabled.                  |
          |---------+-------------+------------------------------------|
          |    1    |      0      | Not used.                          |
          |---------+-------------+------------------------------------|
          |    2    |      0      | Not used.                          |
          |---------+-------------+------------------------------------|
          |    3    | » 0 1       | V.32 modulation disabled.          |
          |         |             |                                    |
          |         |             | V.32 modulation enabled.           |
          +------------------------------------------------------------+
       
          +------------------------------------------------------------+
          |                    V.32 HANDSHAKE TIME                     |
          |------------------------------------------------------------|
          | Type:        | Register                                    |
          |--------------+---------------------------------------------|
          | Format:      | AT [cmds] S28=n [cmds]                      |
          |--------------+---------------------------------------------|
          | Example:     | ATS28=20<CR>                                |
          |--------------+---------------------------------------------|
          | Default:     | 8                                           |
          |--------------+---------------------------------------------|
          | Range:       | 0-255                                       |
          |--------------+---------------------------------------------|
          | Unit:        | .1 second                                   |
          |--------------+---------------------------------------------|
          | Description: | Sets length of V.32 handshake.              |